Buscar
Mostrando ítems 1-10 de 5747
Robust control applied to power flow control in single-phase inverter with LCL filter, using droop control and D-stability
(2012-12-01)
This paper proposes a new methodology to control the power flow between a distributed generator (DG) and the electrical power distribution grid. It is used the droop voltage control to manage the active and reactive power. ...
Control of Single-Phase Power Converters Connected to Low-Voltage Distorted Power Systems With Variable Compensation Objectives
(Ieee-inst Electrical Electronics Engineers Inc, 2016-03-01)
This paper presents a flexible control technique for power electronics converters, which can function as an active power filter, as a local power supply interface, or perform both functions simultaneously. Thus, it can ...
A New Compensation Method for High Current Non-Linear Loads
(IEEE, 2006)
A new active compensation scheme to eliminate current harmonic components and compensate reactive power for high current non-linear loads is presented and analyzed. The new active compensation technique is based in a series ...
A series active power filter based on a sinusoidal current controlled voltage source inverter
(IEEE, 1995)
A series active power filter, working as a sinusoidal current source, in phase with the mains voltage, has been developed and tested. The amplitude of the fundamental current in the series filter is controlled through the ...
Power flow optimization for grid connected inverter using evolutionary algorithm and additional control loop
(2011-12-28)
In this work it is proposed to validate an evolutionary tuning algorithm in plants composed by a grid connected inverter. The optimization aims the tuning of the slopes of P-Ω and Q-V curves so that the system is stable, ...
Power flow optimization for grid connected inverter using evolutionary algorithm and additional control loop
(2011-12-28)
In this work it is proposed to validate an evolutionary tuning algorithm in plants composed by a grid connected inverter. The optimization aims the tuning of the slopes of P-Ω and Q-V curves so that the system is stable, ...
DC link fuzzy control for an active power filter, sensing the line current only
(IEEE, 1997)
A different approach for controlling a shunt active power filter is presented. The DC link is controlled with fuzzy logic, and the current generated for the filter to compensate harmonics and power factor is not sensed. ...
Power conditioning system coupled with a flow battery for wind energy applications: Modelling and control design
(Institution of Engineering and Technology, 2017-06)
Wind generation (WG) is the most widespread renewable energy resource in the world. However, this implementation inevitably leads to an increase in the problems caused by WG, e.g. frequency oscillations, power fluctuations ...