Buscar
Mostrando ítems 41-50 de 1945
Correlation between Flexural–Tensile Performance of Concrete Reinforced with Hooked-End Steel Fibers Using US and European StandardsCorrelación entre el rendimiento de flexión-tracción de Concreto Reforzado con Fibras de Acero de Extremo Gancho Uso de estándares estadounidenses y europeos
(Journal of Materials in Civil Engineering, 2021)
: ACI 318 and the fib Model Code 2010 prescribe recommendations for the design of steel fiber–reinforced concrete (SFRC) using performance measured with a four-point bending test (4PBT) per the ASTM C1609 US standard and ...
Dimensionamento de edificação residencial unifamiliar em estrutura metálicas e estudo comparativo com estrutura de concreto
(Universidade Tecnológica Federal do ParanáPato BrancoBrasilDepartamento Acadêmico de MecânicaEngenharia MecânicaUTFPR, 2021-05-14)
In order to present the differences between the construction systems present in the market and to study the metallic construction system more deeply, this research presents the design of a single-family residential building ...
Analysis of the relative rib area of reinforcing bars pull out tests
(-Brasil-, 2019)
Estudo sobre a substituição de armadura metálica por barras de GFRP em vigas de concreto armadas à flexão quando submetidas ao ataque acelerado de íons cloreto
(Universidade Federal de São CarlosUFSCarPrograma de Pós-Graduação em Engenharia Civil - PPGECivCâmpus São Carlos, 2020-02-28)
The use of reinforced concrete structures with steel bars is recurrent in the construction industry in Brazil. However, alternative materials are studied due to the existence of problems related to the use of this traditional ...
Analytical Modeling of the Postcracking Response Observed in Hybrid Steel/Polypropylene Fiber-Reinforced Concrete
(MDPI, 2020-09)
This study deals with the analytical modeling of hybrid fiber-reinforced concretes (HyFRCs) made with a blend of different types of fibers characterized by different geometries and/or constitutive materials. The presented ...
Estudo sobre o dimensionamento de placas de concreto reforçado com fibras de aço apoiadas em meio elástico
(Universidade Federal de São CarlosUFSCarCâmpus São CarlosEngenharia Civil - ECiv, 2022-04-19)
Due to its brittle behavior and low tensile strength, it is common for concrete to be reinforced with other materials, such as steel. Steel fiber-reinforced concrete is a composite material that uses fibers as structural ...
DURACON: Effect of the Environment on Reinforced Concrete Durability. Results of Chile after 5 years of Exposure
(PONTIFICIA UNIV CATOLICA CHILE, ESCUELA CONSTRUCCION CIVIL, 2009)
This study presents the results obtained in Chile under the international project "Influence of Environmental Action in the durability of concrete, DURACON" that joins 11 countries (Argentina, Bolivia, Brazil, Chile, ...
Vertical-Facing Loads in Steel-Reinforced Soil Walls
(Asce-amer Soc Civil EngineersRestonEUA, 2013)
Quasi-static testing of concrete masonry shear walls with different horizontal reinforcement schemes
(2021)
Constructions built with partially grouted reinforced masonry (PG-RM) shear walls are common in several countries, and consequently, different construction solutions can be expected. In this context, one of the main ...
High‑strength reinforcing steel bars: low cycle fatigue behavior using RGB methodology
(Springer, 2021)
Low cycle fatigue life of high-strength reinforcing steel bars (ASTM A706 Grade 80), using photogrammetry by RGB
methodology is evaluated. Fatigue tests are performed on specimens under constant axial displacement with ...