Buscar
Mostrando ítems 1-10 de 231
Centralized Control of Distributed Single-Phase Inverters Arbitrarily Connected to Three-Phase Four-Wire Microgrids
(Ieee-inst Electrical Electronics Engineers Inc, 2017-01-01)
This paper proposes an effective technique to control the power flow among different phases of a three-phase four-wire distribution power system by means of single-phase converters arbitrarily connected among the phases. ...
Model Predictive Control for Master-Slave Inverters in Microgrids
(IEEE Computer Society, 2022)
This paper proposes a Master-Slave Model Predictive Control for parallel grid-tied inverters in a microgrid. In this configuration, the Master is a grid-forming inverter with a Battery Energy Storage System as dc input, ...
Comparação dos Métodos de Paralelismo de Conversores para o Compartilhamento de Potência em Microrredes
(Universidade Federal de PernambucoUFPEBrasilPrograma de Pos Graduacao em Engenharia Eletrica, 2017)
Comparing lock-in ranges and transient responses of second- and third-order phase-locked loops in master-slave clock distribution networks
(ELSEVIER GMBH, URBAN & FISCHER VERLAG, 2008)
The distribution of clock signals throughout the nodes of a network is essential for several applications. in control and communication with the phase-locked loop (PLL) being the component for electronic synchronization ...
Centralized Control Of Distributed Single-phase Inverters Arbitrarily Connected To Three-phase Four-wire Microgrids
(IEEE-Inst Electrical Electronics Engineers IncPiscataway, 2017)
Master-slave strategy based in artificial intelligence for the fault section estimation in active distribution networks and microgrids
(Cartagena de IndiasCampus Tecnológico, 2023-01-02)
Fault location plays an essential role in the integration of self-healing functionalities in active distribution networks and microgrids. However, the fault location methods formulation presents great challenges for these ...
Cooperative Operation Based Master-Slave in Islanded Microgrid with CPT Current Decomposition
(Ieee, 2015-01-01)
In multi-inverter-based islanded microgrids with unbalanced and distorted loads, due to voltage drop across line, the load bus voltage is unbalanced and distorted, which shows the requirement for power quality increase at ...
Cooperative operation based master-slave in islanded microgrid with CPT current decomposition
(2015-09-30)
In multi-inverter-based islanded microgrids with unbalanced and distorted loads, due to voltage drop across line, the load bus voltage is unbalanced and distorted, which shows the requirement for power quality increase at ...
Enhancement of the resilience through microgrids formation and DG allocation with master-slave DG operation
(2020-09-01)
The microgrids (MGs) formation is an effective alternative to provide a resilient network, however, in some cases it is not enough to recover an acceptable operational state after major faults scenarios, therefore investment ...
Enhancement of the Resilience Through Microgrids Formation and DG Allocation with Master-Slave DG Operation
(Ieee, 2020-01-01)
The microgrids (MGs) formation is an effective alternative to provide a resilient network, however, in some cases it is not enough to recover an acceptable operational state after major faults scenarios, therefore investment ...