dc.description.abstractObjetivo: evaluar y determinar los parámetros tanto máximos como mínimos en los que se encuentran la temperatura y humedad relativa para mantener y cumplir con las buenas prácticas de almacenamiento. Materiales y método: se realizó la evaluación de la temperatura y la humedad relativa de una droguería ubicada en Lurín - Lima, Perú; la medición se ejecutó utilizando 30 registradores electrónicos o datalogger, con intervalos de 5 minutos durante 72 horas seguidas, se analizaron los resultados de acuerdo con los parámetros del manual de buenas prácticas de almacenamiento de productos farmacéuticos basada en la resolución ministerial 132 - 2015 MINSA. Resultado: se registró como temperatura máxima 26.5°C y mínima de 20.7°C y una humedad relativa máxima de 78.9% y mínima de 60.6%, de acuerdo con la normativa y basándonos en el acta de inspección de DIGEMID el almacén en estudio no cumple con los parámetros establecidos. Conclusión: se logró evaluar los parámetros de temperatura y humedad relativa en los que se encuentra una droguería ubicada en Lurín-Lima y se determinaron las unidades de medida máximos y mínimos para cada uno de ellos.
dc.description.abstractObjective: evaluate the parameters in which temperature and relative humidity are found to comply with good storage practices. Materials and methods: the evaluation of the temperature and relative humidity of a drug store located in Lurín - Lima, Peru was carried out; the measurement was carried out using 30 electronic recorders or dataloggers, with 5-minute intervals for 72 consecutive hours. The results were analyzed in accordance with the parameters of the manual of good storage practices for pharmaceutical products based on ministerial resolution 132 - 2015 MINSA. Result: a maximum temperature of 26.5°C and a minimum of 20.7°C and a maximum relative humidity of 78.9% and a minimum of 60.6% were recorded, in accordance with the regulations and based on the DIGEMID inspection report, the warehouse under study does not comply with the parameters. established. Conclusion: it was possible to evaluate the temperature and relative humidity parameters in which a drugstore located in Lurín-Lima is located and the maximum and minimum measurement units for each of them were determined.
dc.languagespa
dc.publisherUniversidad María Auxiliadora
dc.publisherPE
dc.rightshttps://creativecommons.org/licenses/by/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTemperatura ambiente controlada
dc.subjectHumedad relativa
dc.subjectBuenas prácticas de almacenamiento
dc.subjectConformidad
dc.subjectControlled ambient temperature
dc.subjectRelative humidity
dc.subjectGood storage practices
dc.subjectCompliance