dc.description.abstract | Objetivo: evaluar y determinar los parámetros tanto máximos
como mínimos en los que se encuentran la temperatura y
humedad relativa para mantener y cumplir con las buenas
prácticas de almacenamiento.
Materiales y método: se realizó la evaluación de la temperatura
y la humedad relativa de una droguería ubicada en Lurín - Lima,
Perú; la medición se ejecutó utilizando 30 registradores
electrónicos o datalogger, con intervalos de 5 minutos durante
72 horas seguidas, se analizaron los resultados de acuerdo con
los parámetros del manual de buenas prácticas de
almacenamiento de productos farmacéuticos basada en la
resolución ministerial 132 - 2015 MINSA.
Resultado: se registró como temperatura máxima 26.5°C y
mínima de 20.7°C y una humedad relativa máxima de 78.9% y
mínima de 60.6%, de acuerdo con la normativa y basándonos en
el acta de inspección de DIGEMID el almacén en estudio no cumple con los parámetros establecidos.
Conclusión: se logró evaluar los parámetros de temperatura y
humedad relativa en los que se encuentra una droguería ubicada
en Lurín-Lima y se determinaron las unidades de medida
máximos y mínimos para cada uno de ellos. | |
dc.description.abstract | Objective: evaluate the parameters in which temperature and
relative humidity are found to comply with good storage
practices.
Materials and methods: the evaluation of the temperature and
relative humidity of a drug store located in Lurín - Lima, Peru was
carried out; the measurement was carried out using 30 electronic
recorders or dataloggers, with 5-minute intervals for
72 consecutive hours. The results were analyzed in accordance
with the parameters of the manual of good storage practices for
pharmaceutical products based on ministerial resolution 132 -
2015 MINSA.
Result: a maximum temperature of 26.5°C and a minimum of
20.7°C and a maximum relative humidity of 78.9% and a minimum
of 60.6% were recorded, in accordance with the regulations and
based on the DIGEMID inspection report, the warehouse under
study does not comply with the parameters. established.
Conclusion: it was possible to evaluate the temperature and
relative humidity parameters in which a drugstore located in
Lurín-Lima is located and the maximum and minimum
measurement units for each of them were determined. | |
dc.language | spa | |
dc.publisher | Universidad María Auxiliadora | |
dc.publisher | PE | |
dc.rights | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Temperatura ambiente controlada | |
dc.subject | Humedad relativa | |
dc.subject | Buenas prácticas de almacenamiento | |
dc.subject | Conformidad | |
dc.subject | Controlled ambient temperature | |
dc.subject | Relative humidity | |
dc.subject | Good storage practices | |
dc.subject | Compliance | |
dc.title | Evaluación de la temperatura y humedad relativa como parámetros de cumplimiento de las buenas prácticas de almacenamiento en una droguería – Lurín – Lima 2023 | |
dc.type | info:eu-repo/semantics/bachelorThesis | |