dc.description | La presente investigación tiene como objetivo determinar la influencia de la aplicación de
geomalla biaxial de cables eléctricos adicionado con ceniza de fondo de horno ladrillero para
el mejoramiento de las propiedades de los suelos arcillosos en la subrasante de la vía vecinal
1140, entre las progresivas 3+700 a 4+700 del distrito Cachimayo, Anta, Cusco, donde se vio
suelos arcillosos, para lo cual se buscó mejorar su uso como subrasante, utilizando ceniza de
fondo de horno ladrillero en diferentes dosificaciones y geomallas elaboradas con el
recubrimiento de cables eléctricos. Se realizaron los ensayos de Límites de Atterberg, Proctor
Modificado y CBR (según el Manual de ensayos de laboratorio MTC, 2016) para ver la mejora
de las propiedades del suelo arcilloso utilizando ceniza de fondo de horno ladrillero en
porcentajes de 5%, 10%, 15% y 20% junto a la geomalla biaxial de cables eléctricos con celdas
de 2.5 cm de espaciado y colocada a una profundidad de 2.0 cm. Habiéndose contrastado
resultados favorables, para el ensayo de CBR obteniendo mejoras progresivas según se
incrementó el porcentaje de ceniza de fondo del que se obtuvieron los siguientes resultados: en
el suelo natural que alcanzo un CBR para subrasante de 1.724%, al adicionar una geomalla
biaxial de cables eléctricos presento un CBR de 1.750%, así mismo al combinar la geomalla
biaxial con una dosificación del 5% ceniza de fondo, el CBR alcanzo un valor de 3.435%, al
adicionar un 10% de ceniza de fondo presento un CBR de 7.261%, al adicionar un 15% de
ceniza de fondo presento un CBR de 10.178%, y finalmente al adicionar un 20% se alcanzó un
CBR de 10.789%, considerándose esta una mejora significativa teniéndose un suelo bueno para
uso como subrasante. Por lo cual se concluye que estas alternativas se consideran como buenos
estabilizadores a nivel mecánico para suelos arcillosos, teniendo como mejor alternativa para
subrasantes una dosificación del 20% de ceniza de fondo de horno ladrillero con geomalla
biaxial de cables eléctricos. | |
dc.description | The present investigation aims to determine the influence of the application of biaxial geogrid
of electric cables added with bottom ash from the brick kiln for the improvement of the
properties of clayey soils in the subgrade of the 1140 neighborhood road, Cachimayo district,
Anta, Cusco, where clayey soils were seen, for which an improvement was sought for its use
as a subgrade, using bottom ash from the brick kiln in different dosages and geogrids made with
the covering of electrical cables. The Atterberg Limits, Modified Proctor and CBR tests were
carried out (according to the MTC Laboratory Test Manual, 2016) to see the improvement of
the properties of the clayey soil using bottom ash from the brick kiln in percentages of 5%,
10%, 15% and 20% next to the biaxial electrical cable geogrid with 2.5 cm cell spacing and
placed at a depth of 2.0 cm. Having contrasted favorable results, for the CBR test obtaining
progressive improvements as the percentage of bottom ash increased, from which the following
results were obtained: in the natural soil that reached a CBR for subgrade of 1.724%, by adding
a biaxial geogrid of electrical cables presented a CBR of 1,750%, likewise when combining the
biaxial geogrid with a dosage of 5% bottom ash, the CBR reached a value of 3.435%, by adding
10% bottom ash I presented a CBR of 7.261% , by adding 15% of bottom ash I present a CBR
of 10.178%, and finally by adding 20% a CBR of 10.789% was reached, considering this a
significant improvement having a regular soil for use as subgrade. Therefore, it is concluded
that these alternatives are considered good mechanical stabilizers for clayey soils, with the best
alternative for subgrades being a dosage of 20% of bottom ash from the brick kiln with biaxial
geogrid of electrical cables. | |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Universidad Andina del Cusco | |
dc.publisher | PE | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Geomalla biaxial | |
dc.subject | Ceniza de fondo | |
dc.subject | Limites de consistencia | |
dc.subject | Densidad máxima seca | |
dc.subject | https://purl.org/pe-repo/ocde/ford#2.01.01 | |
dc.title | Aplicación de geomalla biaxial de cables eléctricos con ceniza de fondo para el mejoramiento de suelos arcillosos en la vía vecinal 1140, Cusco, 2022 | |
dc.type | info:eu-repo/semantics/bachelorThesis | |