Numerical evaluation of the overturning of a wall of an Inca room of the temple of Coricancha cusco with lace and without lace

dc.contributorLipa Cusi, Leonel
dc.creatorTenorio Coronel, Fiorella Teresa
dc.creatorDiaz Serpa, Jordan Luiggi
dc.date2024-01-05T13:51:40Z
dc.date2024-01-05T13:51:40Z
dc.date2023-11-14
dc.date.accessioned2024-05-14T23:27:49Z
dc.date.available2024-05-14T23:27:49Z
dc.identifier0000 0001 2196 144X
dc.identifierhttp://hdl.handle.net/10757/670683
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9409072
dc.descriptionEn la actualidad muchas construcciones incas han desaparecido debido a la caída del imperio incaico y a la construcción de nuevos templos en la época colonial. Sin embargo, todavía hay estructuras incas que siguen de pie a pesar de su antigüedad. Por esa razón, este trabajo de investigación tiene por finalidad evaluar este tipo de sistemas haciendo uso de la teoría de los elementos finitos y definir si es posible modelar estas estructuras, de modo que sirva como punto de partida para futuras investigaciones. En la investigación se analiza dos muros incas de dos capas, uno con encaje y el otro sin encajes. Los muros con dimensiones 9.90 m x 2.8 m de altura de sección y 0.80 m, con densidad 2300 kg/m3, con una rigidez normal de 2 x 〖10〗^7 N/m3 , coeficiente de fricción 0.4 y los resultados obtenidos fueron el muro con encaje soporta un ángulo de 16.4°, mientras que el muro sin encaje soporta un ángulo el 10.4° se concluyó que el muro inca con encajes resiste más al volteo a diferencia del muro sin encajes.
dc.descriptionToday many Inca constructions have disappeared due to the fall of the Inca empire and the construction of new temples in colonial times. However, there are still Inca structures that are still standing despite their age. For that reason, the purpose of this research work is to evaluate this type of systems using the finite element theory and to define if it is possible to model these structures, in order to serve as a starting point for future research. The research analyzes two two-layer Inca walls, one with sockets and the other without sockets. The walls with dimensions 9.90 m x 2.8 m section height and 0.80 m, with density 2300 kg/m3, with a normal stiffness of 2 x 10^7 N/m3, friction coefficient 0.4 and the results obtained were that the wall with lace supports an angle of 16.4°, while the wall without lace supports an angle of 10.4°. It was concluded that the Inca wall with lace resists overturning more than the wall without lace.
dc.descriptionTrabajo de Suficiencia Profesional
dc.formatapplication/pdf
dc.formatapplication/epub
dc.formatapplication/msword
dc.languagespa
dc.publisherUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.publisherPE
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.sourceRepositorio Académico - UPC
dc.subjectConstrucciones incas
dc.subjectImperio incaico
dc.subjectEtructuras incas
dc.subjectTeoría de los elementos finitos
dc.subjectCoeficiente de fricción
dc.subjectInca constructions
dc.subjectInca Empire
dc.subjectInca structures
dc.subjectFinite element theory
dc.subjectCoefficient of friction
dc.subjecthttps://purl.org/pe-repo/ocde/ford#2.01.01
dc.subjecthttps://purl.org/pe-repo/ocde/ford#2.00.00
dc.titleEvaluación Numérica al volteo de un muro de una habitación inca del templo del Coricancha Cusco con encajes y sin encajes.
dc.titleNumerical evaluation of the overturning of a wall of an Inca room of the temple of Coricancha cusco with lace and without lace
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.typeTrabajo de Suficiencia Profesional


Este ítem pertenece a la siguiente institución