dc.creatorMontesinos-Segura, Renee
dc.creatorDavila-Flores, Diego
dc.creatorQuevedo-Candela, Fernando
dc.creatorCabrera-Saldaña, Mario
dc.creatorZelaya-Castro, Pío
dc.creatorSoto-Becerra, Richard
dc.date.accessioned2023-10-23T20:53:15Z
dc.date.accessioned2024-05-09T19:07:48Z
dc.date.available2023-10-23T20:53:15Z
dc.date.available2024-05-09T19:07:48Z
dc.date.created2023-10-23T20:53:15Z
dc.date.issued2023-06-30
dc.identifierArchivos Peruanos de Cardiología Cirugía Cardiovascular. 2023; 4(2).
dc.identifierhttps://hdl.handle.net/20.500.12959/4319
dc.identifierhttps://doi.org/10.47487/apcyccv.v4i2.288
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9390683
dc.description.abstractLos dispositivos de oclusión del septo interatrial dificultan el abordaje transeptal para la ablación de la fibrilación auricular, por lo que es necesario contar con métodos de imagen que guíen con seguridad la punción transeptal, como la ecocardiografía intracardíaca (EIC). Se describe el caso de un paciente de 49 años con fibrilación auricular paroxística sintomática, refractaria a fármacos antiarrítmicos, portador de un dispositivo de oclusión del septo interatrial, con intento previo de ablación fallido. La ablación de la fibrilación auricular se realizó con el sistema de mapeo 3D Carto V7, la punción transeptal fue guiada por EIC y el procedimiento fue exitoso. Este reporte de caso resalta la importancia de la multimodalidad en imágenes, con el fin de se logre una punción transeptal exitosa y eficaz para llevar a cabo la ablación de fibrilación auricular en pacientes portadores de dispositivos de oclusión septal interatrial.
dc.description.abstractInteratrial septal occlusion devices hinder the transseptal approach for atrial fibrillation ablation, making it necessary to have imaging methods that safely guide transseptal puncture, such as intracardiac echocardiography (ICE). We describe the case of a 49-year-old patient with symptomatic paroxysmal atrial fibrillation, refractory to antiarrhythmic drugs, wearing an interatrial septal occlusion device, with a previous unsuccessful ablation attempt. Atrial fibrillation ablation was performed using the Carto V7 3D mapping system, the transseptal puncture was guided by ICE, and the procedure was successful. This case report highlights the importance of multimodality imaging to achieve successful and effective transseptal puncture for atrial fibrillation ablation in patients with interatrial septal occlusion devices
dc.languagespa
dc.publisherSeguro Social de Salud (EsSalud)
dc.relationhttps://apcyccv.org.pe/index.php/apccc/article/view/288
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDefectos del tabique interatrial
dc.subjectDispositivo oclusor septal
dc.subjectFibrilación auricular
dc.subjectAblación por catéter
dc.subjectecocardiografía
dc.subjectHeart septal defects
dc.subjectAtrial
dc.subjectSeptal occluder device
dc.subjectAtrial fibrillation
dc.subjectCatheter ablation
dc.subjectEchocardiography
dc.titleAblación de fibrilación auricular en paciente con dispositivo de oclusión septal interatrial
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución