dc.contributor | Del Aguila Panduro, Ruben | |
dc.creator | Arevalo Villanueva, Winter Agustin | |
dc.creator | Alvarado Arevalo, Diego Antonio | |
dc.date.accessioned | 2017-12-04T14:21:03Z | |
dc.date.accessioned | 2024-05-09T14:57:25Z | |
dc.date.available | 2017-12-04T14:21:03Z | |
dc.date.available | 2024-05-09T14:57:25Z | |
dc.date.created | 2017-12-04T14:21:03Z | |
dc.date.issued | 2017 | |
dc.identifier | Arevalo-Villanueva, W. A. & Alvarado-Arevalo, D. A. (2017). Zonificación de la capacidad portante del suelo en la localidad de Chazuta, distrito de Chazuta, provincia de San Martín, región de San Martín. Tesis para optar el grado de Ingeniero Civil. Facultad de Ingeniería Civil y Arquitectura, Universidad Nacional de San Martín, Tarapoto, Perú. | |
dc.identifier | http://hdl.handle.net/11458/2525 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/9385778 | |
dc.description.abstract | El presente trabajo de investigación denominada " ZONIFICACIÓN DE LA CAPACIDAD PORTANTE DEL SUELO EN LA LOCALIDAD DE CHAZUTA, DISTRITO DE CHAZUTA, PROVINCIA DE SAN MARTÍN- REGION DE SAN MARTÍN.”, tiene como objetivo determinar la capacidad portante que permita elaborar un mapa de zonificación de capacidad portante de suelos. La metodología de investigación empleada fue descriptiva, en la que se busca especificar y analizar las características geológicas y geotécnicas del suelo. Se ha realizado el correcto desarrollo de los ensayos en laboratorio de contenido de humedad, límites de consistencia (atterberg), análisis granulométrico, densidad de campo, corte directo y clasificación de suelos, basándonos en las normas establecidas vigentes, siguiendo con el desarrollo del trabajo, estos ensayos han permitido determinar las propiedades físicas y mecánicas del suelo de fundación, así como también el tipo de suelo y sus características. Se realizó una clasificación de los suelos por el método de SUCS, en el cual indica la presencia de suelos de granulometría gruesa y fina, los suelos de granulometría fina del tipo arcillosos CL y CH, y suelos de granulometría gruesa del tipo GP, GM y GC, con porcentaje de humedad baja a media, en el trabajo de investigación se han determinado dos zonas geotécnicas bien marcadas denominadas Zona I y Zona II los cuales están delimitadas en la Zona I por la C-03, C-04, C-07, C-08, C-09, C-10, C-12, C-14, C-16, C-17, C-18, C-20, C-21, C-22, C-23, C-24, C-25, C-26, C-27, C-28, C-29, C-30, C-31, C-32, C-33, C-34, C-35, C-36, C-37, C-38, C-39 Y C-40 y en la Zona II por la C-01, C-02, C-05, C-06, C-11, C-13, C-15 Y C-19. Entonces se ha determinado que la capacidad admisible en la Zona I con una profundidad de cimentación de -1.50 metros y con un ancho de cimentación de 1.00 metro se encuentra entre 0.754 y 0.900 Kg/cm2 con una capacidad admisible promedio de 0.827 kg/cm2 o 8.27 tn/m2, mientras que la capacidad admisible en la Zona II con una profundidad de cimentación de -1.50 metros y con un ancho de cimentación de 1.00 metro se encuentra entre 1.069 y 1.198 Kg/cm2 con una capacidad admisible promedio de 1.134 kg/cm2 o 11.34 tn/m2. | |
dc.description.abstract | The present research work entitled "ZONING OF SOIL CAPACITY IN THE LOCALITY OF CHAZUTA, CHAZUTA DISTRICT, PROVINCE OF SAN MARTÍN - REGION OF SAN MARTÍN", aims to determine the carrying capacity that allows the elaboration of a zoning map of load bearing capacity. The research methodology used was descriptive, in which the aim was to specify and analyze the geological and geotechnical characteristics of the soil. The correct development of laboratory tests of moisture content, consistency limits (atterberg), particle size analysis, field density, direct cutting and soil classification have been carried out, based on established standards in force, following the development of the work , these tests have allowed to determine the physical and mechanical properties of the foundation soil, as well as the type of soil and its characteristics. Soils were classified by the SUCS method, which indicates the presence of soils with fine and fine granulometry, fine granulometry soils of the CL and CH type, and coarse granulometric soils of type GP, GM and GC, with low to medium moisture content, two well-defined geotechnical zones called Zone I and Zone II have been determined in the research work, which are delimited in Zone I by C-03, C-04, C-07 , C-20, C-20, C-20, C-12, C-12, C-14, C-16, C-17, C-17 -24, C-25, C-26, C-27, C-28, C-29, C-30, C-31, C-32, C-33, C-34, C-35, C-36 , C-37, C-38, C-39 and C-40 and in Zone II by C-01, C-02, C-05, C-06, C-11, C-13, C-15 And C-19. It has been determined that the permissible capacity in Zone I with a foundation depth of -1.50 meters and a foundation width of 1.00 meter is between 0.754 and 0.900 kg / cm2 with an average permissible capacity of 0.827 kg / cm2 or 8.27 ton / m2, while the permissible capacity in Zone II with a foundation depth of -1.50 meters and a foundation width of 1.00 meters is between 1,069 and 1,198 kg / cm2 with an average permissible capacity of 1,134 kg / cm2 or 11.34 tons / m2. | |
dc.language | spa | |
dc.publisher | Universidad Nacional de San Martín. Fondo Editorial | |
dc.publisher | PE | |
dc.rights | https://creativecommons.org/licenses/by/4.0/deed.es | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.source | Repositorio - UNSM | |
dc.subject | Geológico y geotécnico | |
dc.subject | Análisis de tamaño de partícula | |
dc.subject | Densidad de campo | |
dc.subject | Zonas urbanas | |
dc.subject | Uso de la tierra | |
dc.subject | Geología urbana | |
dc.title | Zonificación de la capacidad portante del suelo en la localidad de Chazuta, distrito de Chazuta, provincia de San Martín, región de San Martín | |
dc.type | info:eu-repo/semantics/bachelorThesis | |