dc.description.abstractEn la actualidad, la norma de diseño sismorresistente E.030, indica un análisis sísmico sin la consideración de la bidireccionalidad y ángulo de incidencia. Este aspecto es de vital importancia debido a que a la hora de que se genera un sismo, las ondas sísmicas no necesariamente vienen en los mismos ejes ortogonales de la estructura, sino a un cierto ángulo de estas. Se analizó el efecto de la bidireccionalidad y ángulo de incidencia en el análisis sísmico de 6 estructuras de concreto armado con irregularidad torsional con disposición dual de diferentes niveles, mediante el uso del análisis dinámico modal (ADM) y el análisis tiempo historia lineal (ATHL). Para el análisis, se utilizó ángulos de incidencia cada 15°. Se hizo el uso de 8 registros sísmicos de igual tipo de falla y cercanos a la zona de estudio, estos fueron obtenidos de la red nacional de acelerógrafos del CISMID y del IGP. Finalmente, las respuestas obtenidas de ambos análisis se compararon de manera que se obtuvo el porcentaje de amplificación para cada uno de estas con las consideraciones de bidireccionalidad y ángulo de incidencia, se analizó la influencia del ángulo de incidencia en la torsión estructural de las edificaciones y se comparó con las normas internacionales para conocer la aproximación de sus resultados.
dc.description.abstractCurrently, the seismic-resistant design standard E.030, indicates a seismic analysis without the consideration of bidirectionality and angle of incidence. This aspect is of vital importance because at the time of an earthquake, seismic waves do not necessarily come on the same orthogonal axes of the structure, but at a certain angle of these. It was analyzed the effect of bidirectionality and angle of incidence in the seismic analysis of 6 concrete structures armed with torsional irregularity with dual arrangement of different levels, by using modal dynamic analysis (MDA) and linear time history analysis (LTHA). For angle of incidence analysis, it was used every 15°. It was used 8 seismic records of the same type of fault and close to the study area, these were obtained from the national network of accelerographs of CISMID and IGP. Finally, the results obtained from both analyses were compared so that the percentage of application for each of these was obtained with the considerations of bidirectionality and angle of incidence, the influence of the angle of incidence on the structural torsion of the buildings was analyzed and it was compared with international standards to know the approximation of their results
dc.languagespa
dc.publisherUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.publisherPE
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International
dc.sourceUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.sourceRepositorio Académico - UPC
dc.subjectÁngulo de incidencia
dc.subjectEdificaciones antisísmicas
dc.subjectEstructura sísmica
dc.subjectAngle of incidence
dc.subjectAnti-seismic buildings
dc.subjectSeismic structure
dc.titleLa Influencia del Ángulo de Incidencia Sísmica en la Respuesta Estructural de Edificaciones de Sistema Dual con Irregularidad Torsional en la ciudad de Lima