dc.creatorKumar, Gujuluva Gangatharan Vinoth
dc.creatorBhaskar, R.
dc.creatorHarathi, Jonnagaddala
dc.creatorBorda, Ricardo Fernando Cosio
dc.creatorHussain, Shamima
dc.creatorSundaramoorthy, Arunmetha
dc.date.accessioned2023-10-24T21:44:25Z
dc.date.accessioned2024-05-03T20:01:07Z
dc.date.available2023-10-24T21:44:25Z
dc.date.available2024-05-03T20:01:07Z
dc.date.created2023-10-24T21:44:25Z
dc.date.issued2023-04-05
dc.identifierKumar, G. G., Bhaskar, R., Harathi, J., Borda, R. F., Hussain, S., Sundaramoorthy, A. (2023). A simple fluorescent sensor for the meticulous recognition of Cu2+ ion and its functioning in logic gate and keypad lock. Journal of Photochemistry and Photobiology A: Chemistry, 441, 114750. https://doi.org/10.1016/j.jphotochem.2023.114750
dc.identifier.
dc.identifierhttps://hdl.handle.net/11537/34751
dc.identifierJournal of Photochemistry and Photobiology A: Chemistry
dc.identifierhttps://doi.org/10.1016/j.jphotochem.2023.114750
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9281800
dc.description.abstractA highly selective and perceptive “off–on” mode fluorescent receptor (E)-1-(5-methylfuran-2-yl)-N-(2-(phenylthio)phenyl)methanimine (R) has been constructed for the expeditious recognition of Cu2+ ions in the semi-aqueous medium. The strong fluorescence was observed at 468 nm for Cu2+ ions over other tested metal ions by R, which could be attributed to the constraint of the CHdouble bondN isomerization mechanism and provoked chelation enhanced fluorescence effect (CHEF) upon interaction with copper ions. According to Job’s plot, the binding proportion between R and copper ion is 2:1 and further validated by mass analysis and quantum chemical studies. Based on the emission titration, the limits of detection (LOD) were determined to be 0.194 μM. The obtained results designate that the receptor R serves as a significant nominee for an expeditious recognition of Cu2+ ions. Further, R was fruitfully useful in molecular keypad locks, and molecular logic gate circuits and it could be applied to find out the trace quantity of Cu2+ ions in water samples.
dc.languagespa
dc.publisherElsevier B.V.
dc.publisherIN
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.sourceUniversidad Privada del Norte
dc.sourceRepositorio Institucional - UPN
dc.subjectBloqueo de teclado molecular
dc.subjectPuerta lógica molecular
dc.subjectQuimiosensor
dc.titleA simple fluorescent sensor for the meticulous recognition of Cu2+ ion and its functioning in logic gate and keypad lock
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución