dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorSilva, Lucas Hian da
dc.creatorRibeiro, Sebastiao
dc.creatorSouto Borges, Alexandre Luis
dc.creatorCesar, Paulo Francisco
dc.creatorTango, Rubens Nisie
dc.date2015-03-18T15:53:25Z
dc.date2016-10-25T20:24:56Z
dc.date2015-03-18T15:53:25Z
dc.date2016-10-25T20:24:56Z
dc.date2014-11-01
dc.date.accessioned2017-04-06T07:03:15Z
dc.date.available2017-04-06T07:03:15Z
dc.identifierDental Materials. Oxford: Elsevier Sci Ltd, v. 30, n. 11, p. E283-E288, 2014.
dc.identifier0109-5641
dc.identifierhttp://hdl.handle.net/11449/116501
dc.identifierhttp://acervodigital.unesp.br/handle/11449/116501
dc.identifier10.1016/j.dental.2014.05.016
dc.identifierWOS:000345525400001
dc.identifierhttp://dx.doi.org/10.1016/j.dental.2014.05.016
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/927148
dc.descriptionObjectives. The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw.Methods. Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured.Results. FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region.Significance. In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.languageeng
dc.publisherElsevier B.V.
dc.relationDental Materials
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectY-TZP
dc.subjectImplant abutment
dc.subjectSlip-cast
dc.subjectCeramics
dc.subjectDental implant
dc.subjectProsthodontics
dc.subjectBiomaterials
dc.subjectEsthetic dentistry
dc.subjectOral rehabilitation
dc.titleFEA and microstructure characterization of a one-piece Y-TZP abutment
dc.typeOtro


Este ítem pertenece a la siguiente institución