Intubación traqueal con dispositivo supraglóticoI-gel en pacientes pediátricos: Serie de casosprospectiva

dc.creatorZamudio Burbano, Mario Andrés
dc.creatorGiraldo Salazar, Olga
dc.creatorGaviria Rivera, Elmer
dc.creatorGómez Castellanos, Guillermo
dc.creatorRodríguez, Cesar Ángel
dc.creatorMedina Ramírez, Santiago
dc.creatorRamírez Latorre, Juan Luis
dc.creatorHerrera Caviedes, Laura Andrea
dc.date2023-07-12T18:53:37Z
dc.date2023-07-12T18:53:37Z
dc.date2018
dc.date.accessioned2024-04-23T14:17:20Z
dc.date.available2024-04-23T14:17:20Z
dc.identifierZamudio-Burbano MA, Giraldo-Salazar O, Gaviria-Rivera E, Gómez-Castellanos G, Ángel Rodríguez C, Medina Ramírez S, et al. Intubación traqueal con dispositivo supraglótico I-gel en pacientes pediátricos: Serie de casos prospectiva. Rev Colomb Anestesiol. 2018;46:40–44.
dc.identifier0120-3347
dc.identifierhttps://hdl.handle.net/10495/35897
dc.identifier10.1097/CJ9.0000000000000007
dc.identifier2422-0248
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9229430
dc.descriptionRESUMEN: Introducción: No hay un dispositivo en la actualidad que demuestre apropiado porcentaje de éxito de intubación a ciegas en pediatría. Objetivos: El propósito de esta serie de casos es conocer el porcentaje de éxito de intubación a ciegas a través de la máscara laríngea I-gel en niños pesando entre 2 y 35 kilos, además evaluarla presión de sello, la visión fibroscópica a través del dispositivo y reportar la aparición de complicaciones. Materiales y Métodos: Serie prospectiva de casos en pediatría, en pacientes de 2 a 35 kilos. Resultados: En nuestro estudio el porcentaje global de intubación a ciegas fue del 23%, el porcentaje de visión ideal y visión baja, que permiten fácil introducción del broncoscopio en la vía aérea y luego a través del fibroscopio introducir un tubo traqueal, fue de un 70%. Conclusiones: Consideramos que el I-gel supraglótico no es un dispositivo adecuado para intubación a ciegas. Sin embargo, tiene un valor aceptable para recomendar realizar intubación fibro-óptica a través del dispositivo supraglótico I-gel.
dc.descriptionABSTRACT: Introduction: Currently there are no devices showing anacceptable success rate in blind intubation in pediatrics. Objetive: The purpose of this particular series of cases in toidentify the percentage of successful blind intubations using theI-gel laryngeal mask in children between 2 and 35 kilos of bodyweight, in addition to evaluating seal pressure,fiber opticsvision through the device and reporting the occurrence ofcomplications. Materialsand methods: A prospective case series in pediatrics;patients from 2 to 35 kilos. Results: According to our study, the overall percentage of blindintubation was 23%, while the percentages of ideal and low visionto facilitate the insertion of the bronchoscope into the airway, andthen inserting a tracheal tube through thefiber optics was 70%. Conclusions:We feel that the supraglottic I-gel is not theappropriate device for blind intubation; however, it is anacceptable recommendation to conductfiber optics intubation.
dc.descriptionCOL0094314
dc.format5
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languageeng
dc.languagespa
dc.publisherSociedad Colombiana de Anestesiología y Reanimación
dc.publisherGrupo de Investigación en Medicina Perioperatoria (GRIMPA)
dc.publisherBogotá, Colombia
dc.relationRev. Colomb. Anestesiol.
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectIntubación Intratraqueal
dc.subjectIntubation, Intratracheal
dc.subjectManejo de la Vía Aérea
dc.subjectAirway Management
dc.subjectVentilation
dc.subjectVentilation
dc.subjectAnestesia
dc.subjectAnesthesia
dc.subjectPediatría
dc.subjectPediatrics
dc.subjectInformes de Casos
dc.subjectCase Reports
dc.titleTracheal intubation with I-gel supraglottic device in pediatric patients: a prospective case series
dc.titleIntubación traqueal con dispositivo supraglóticoI-gel en pacientes pediátricos: Serie de casosprospectiva
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typehttp://purl.org/coar/resource_type/c_2df8fbb1
dc.typehttps://purl.org/redcol/resource_type/ART
dc.typeArtículo de investigación


Este ítem pertenece a la siguiente institución