Tracheal intubation with I-gel supraglottic device in pediatric patients: a prospective case series
Intubación traqueal con dispositivo supraglóticoI-gel en pacientes pediátricos: Serie de casosprospectiva
dc.creator | Zamudio Burbano, Mario Andrés | |
dc.creator | Giraldo Salazar, Olga | |
dc.creator | Gaviria Rivera, Elmer | |
dc.creator | Gómez Castellanos, Guillermo | |
dc.creator | Rodríguez, Cesar Ángel | |
dc.creator | Medina Ramírez, Santiago | |
dc.creator | Ramírez Latorre, Juan Luis | |
dc.creator | Herrera Caviedes, Laura Andrea | |
dc.date | 2023-07-12T18:53:37Z | |
dc.date | 2023-07-12T18:53:37Z | |
dc.date | 2018 | |
dc.date.accessioned | 2024-04-23T14:17:20Z | |
dc.date.available | 2024-04-23T14:17:20Z | |
dc.identifier | Zamudio-Burbano MA, Giraldo-Salazar O, Gaviria-Rivera E, Gómez-Castellanos G, Ángel Rodríguez C, Medina Ramírez S, et al. Intubación traqueal con dispositivo supraglótico I-gel en pacientes pediátricos: Serie de casos prospectiva. Rev Colomb Anestesiol. 2018;46:40–44. | |
dc.identifier | 0120-3347 | |
dc.identifier | https://hdl.handle.net/10495/35897 | |
dc.identifier | 10.1097/CJ9.0000000000000007 | |
dc.identifier | 2422-0248 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/9229430 | |
dc.description | RESUMEN: Introducción: No hay un dispositivo en la actualidad que demuestre apropiado porcentaje de éxito de intubación a ciegas en pediatría. Objetivos: El propósito de esta serie de casos es conocer el porcentaje de éxito de intubación a ciegas a través de la máscara laríngea I-gel en niños pesando entre 2 y 35 kilos, además evaluarla presión de sello, la visión fibroscópica a través del dispositivo y reportar la aparición de complicaciones. Materiales y Métodos: Serie prospectiva de casos en pediatría, en pacientes de 2 a 35 kilos. Resultados: En nuestro estudio el porcentaje global de intubación a ciegas fue del 23%, el porcentaje de visión ideal y visión baja, que permiten fácil introducción del broncoscopio en la vía aérea y luego a través del fibroscopio introducir un tubo traqueal, fue de un 70%. Conclusiones: Consideramos que el I-gel supraglótico no es un dispositivo adecuado para intubación a ciegas. Sin embargo, tiene un valor aceptable para recomendar realizar intubación fibro-óptica a través del dispositivo supraglótico I-gel. | |
dc.description | ABSTRACT: Introduction: Currently there are no devices showing anacceptable success rate in blind intubation in pediatrics. Objetive: The purpose of this particular series of cases in toidentify the percentage of successful blind intubations using theI-gel laryngeal mask in children between 2 and 35 kilos of bodyweight, in addition to evaluating seal pressure,fiber opticsvision through the device and reporting the occurrence ofcomplications. Materialsand methods: A prospective case series in pediatrics;patients from 2 to 35 kilos. Results: According to our study, the overall percentage of blindintubation was 23%, while the percentages of ideal and low visionto facilitate the insertion of the bronchoscope into the airway, andthen inserting a tracheal tube through thefiber optics was 70%. Conclusions:We feel that the supraglottic I-gel is not theappropriate device for blind intubation; however, it is anacceptable recommendation to conductfiber optics intubation. | |
dc.description | COL0094314 | |
dc.format | 5 | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.language | eng | |
dc.language | spa | |
dc.publisher | Sociedad Colombiana de Anestesiología y Reanimación | |
dc.publisher | Grupo de Investigación en Medicina Perioperatoria (GRIMPA) | |
dc.publisher | Bogotá, Colombia | |
dc.relation | Rev. Colomb. Anestesiol. | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Intubación Intratraqueal | |
dc.subject | Intubation, Intratracheal | |
dc.subject | Manejo de la Vía Aérea | |
dc.subject | Airway Management | |
dc.subject | Ventilation | |
dc.subject | Ventilation | |
dc.subject | Anestesia | |
dc.subject | Anesthesia | |
dc.subject | Pediatría | |
dc.subject | Pediatrics | |
dc.subject | Informes de Casos | |
dc.subject | Case Reports | |
dc.title | Tracheal intubation with I-gel supraglottic device in pediatric patients: a prospective case series | |
dc.title | Intubación traqueal con dispositivo supraglóticoI-gel en pacientes pediátricos: Serie de casosprospectiva | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.type | https://purl.org/redcol/resource_type/ART | |
dc.type | Artículo de investigación |