dc.descriptionEn la siguiente investigación se estudia la importancia de considerar la Interacción Dinámica Suelo-Estructura en los diferentes tipos de suelo, Grava (S1), Arena Limosa (S2), Arcilla Media (S3) y Arcilla Blanda (S4), descritos en el Código Hondureño de la Construcción (CHOC, 2008) para la revisión de las respuestas estructurales (periodo, cortante basal, deriva y deformación). El CHOC indica que deberá considerarse la posible amplificación de la respuesta del edificio debido a los efectos de la interacción suelo-estructura y el alargamiento del período del edificio causado por el comportamiento elástico. Sin embargo, se realizaron los cálculos de acuerdo a las especificaciones de la ASCE 41-13, ya que la norma nacional no indica procedimientos. Se compara la respuesta de un edificio de marcos rígidos de concreto reforzado de 5 pisos con el periodo fundamental, el cortante basal y la deformación para la interacción suelo-estructura (considerando la elasticidad del suelo) y la cimentación con empotramiento perfecto (apoyo rígido). Se concluyó que el período fundamental aumenta a mayor elasticidad del suelo, y el cortante basal disminuye a mayor periodo fundamental. De igual manera, se concluyó que para una roca y arena limosa no es crítico considerar la interacción suelo-estructura, dado que los resultados obtenidos fueron similares entre ambos modelos. Sin embargo, para suelo arcilloso blando se concluyó que en los modelos que si se considera la interacción suelo-estructura, la respuesta de la estructura varia con la cimentación empotrada, debido a la elasticidad del suelo
dc.descriptionThe following research studies the importance of the consideration of the Soil-Structure Dynamic Interaction (SSI) in the different types of soil (S1, S2, S3 and S4) described in the Honduran Construction Code (CHOC, 2008) for the review of the response of the structure. The CHOC (2008) states that the possible amplification of the building response should be considered due to the effects of the soil-structure interaction and the lengthening of the building period caused by elastic behavior. Due to the lack of procedures from behave the national code, calculations had to be taken from ASCE 41-13. The response of the structure is compared, such as fundamental period, the basal shear and the deformation for the soil-structure interaction and a foundation with perfect recessing. In conclusion, the fundamental period increases according to the elasticity of the soil, and basal shear decrease as the fundamental period increases. For a rock and limous sand it is not critical to consider the interaction of soil-structure, since the results obtained were similar between the two models. However, for clay soils it was observed that in models that the soil-structure interaction is considered, the response of the structure varies significantly with the recessed foundation, due to soil elasticity.
dc.formatPDF
dc.formatapplication/pdf
dc.languageEspañol
dc.languagees-HN
dc.publisherUniversidad Tecnológica Centroaméricana UNITEC
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.sourceUniversidad Tecnológica Centroaméricana UNITEC
dc.subjectSuelo
dc.subjectCimentación
dc.subjectAnálisis Estructural
dc.titleComparación de respuesta estructural de una edificación con cimentación empotrada e interacción suelo-estructura
dc.typeProyecto de Investigación