dc.description | En la zona de Macuelizo, Santa Barbara el 26.59% de la población no tiene acceso a la energía eléctrica. Debido a la falta de conocimientos sobre alternativas viables como los sistemas solares aislados de la red eléctrica, es difícil que el cliente promedio de estas zonas sepa en realidad cuál es su opción más viable para obtener acceso a la energía eléctrica. Es por lo que se hizo un estudio que comparó la viabilidad de un sistema solar fotovoltaico aislado de la red eléctrica versus la extensión de línea de distribución eléctrica primaria para electrificar una residencia de consumo alto en Macuelizo, Santa Bárbara. El estudio se realizó con un enfoque cuantitativo, no experimental, transversal y descriptivo. Se llevó a cabo mediante la comparación de una proyección a 25 años de los Costos Presentes Netos (CPN) de ambos escenarios propuestos.
En el primer escenario se diseñó un sistema solar aislado con un generador solar de 11.7 kWp, un banco de baterías de 1255 Ah C100 y dos inversores híbridos de 5 kW cada uno. Del diseño se realizaron simulaciones computacionales en PVSyst y HelioScope. Con estas simulaciones se obtuvieron los resultados promedio de 67.9% de Performance Ratio, 1,338 kWh/kWp de Rendimiento Específico y 15.66 MWh de Generación Anual. El costo inicial requerido calculado fue de $26,565.68 y se proyectó un CPN de -$73,878.60. | |
dc.description | In the Macuelizo, Santa Bárbara area, 26.59% of the population does not have access to electricity. Due to a lack of knowledge of viable alternatives such as off-grid solar systems, it is difficult for the average customer in these areas to know which is their most viable option for accessing electric energy. This is why a study was carried out that compared the feasibility of an off-grid photovoltaic solar system versus the extension of the primary electrical distribution line to electrify a high consumption residence in Macuelizo, Santa Bárbara. The study was carried out with a quantitative, non-experimental, cross-sectional and descriptive approach. It was carried out by comparing a 25-year projection of the Net Present Costs (NPC) of both proposed scenarios.
In the first scenario, an off-grid solar system was designed with an 11.7 kWp solar generator, a 1255 Ah C100 battery bank and two hybrid inverters of 5 kW each. Computational simulations in PVSyst and HelioScope were run for this design. With these simulations, we obtained the average results of 67.9% for Performance Ratio, 1,338 kWh/kWp for Specific Performance and 15.66 MWh for Annual Generation. The initial required cost was calculated at $26,565.68 and an NPC of -$73,878.60 was projected. | |
dc.format | PDF | |
dc.language | Español | |
dc.language | es-HN | |
dc.publisher | Universidad Tecnológica Centroaméricana Unitec | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
dc.source | Universidad Tecnológica Centroaméricana UNITEC | |
dc.subject | Energía eléctrica | |
dc.subject | Distribución eléctrica | |
dc.subject | Red eléctrica | |
dc.title | Comparación de viabilidad de un sistema solar fotovoltaico aislado de la red eléctrica versus una extensión de línea de distribución eléctrica primaria para una residencia de consumo alto en Macuelizo, Santa Bárbara | |
dc.type | Proyecto de Graduación | |
dc.coverage | Santa Bárbara | |