dc.descriptionEl estudio realizado en Plantas Térmicas Honduras, tuvo como objetivo determinar el ahorro que representa para la empresa instalar un incinerador de lodos HFO/LO al generar el vapor necesario para los equipos auxiliares. La planta térmica consume combustible pesado con grandes cantidades de metales (al + si hasta de 60ppm) y agua (hasta 0.5%) se trata este combustible y da como resultado un residuo de aproximadamente 1% a 0.5% del volumen total de combustible. Este producto luego se trata para eliminar el exceso de agua dando un residuo con gran cantidad de metales erosivos (Al + Si) y un contenido de agua menor al 10%; todavía con un valor calorífico neto de 32,82 MJ / kg. Se realizó el análisis económico y se concluyó que se acepta la hipótesis de investigación al obtenerse una tasa interna de retorno del 81% siendo ésta mayor que el costo de capital del financiamiento del Proyecto, el periodo de retorno de la inversión (PRI) fue de 1.5 años y la relación costo-beneficio fue de 1.71. El proyecto cumplió con todos los aspectos económicos y se recomienda su implementación al contar con los fondos disponibles
dc.descriptionThe objective of the study carried out at the Honduras Thermal Plants, was to determine the savings that the company represents installing an HFO / LO sludge incinerator generating the necessary steam for the auxiliary equipment. The thermal plant consumes heavy fuel oil with large amounts of metals (Al + Si up to 60ppm) and water (up to 0.5%). This fuel is treated and results in a residue of approximately 1% to 0.5% of the total fuel volume. This product is then treated to remove excess water, giving a residue with a large amount of erosive metals (Al + Si) and a water content of less than 10%; still with a net calorific value of 32.82 MJ / kg. The economic analysis was carried out, it was concluded that the alternative hypothesis is accepted as an internal rate of return of 81% is obtained, this being greater than the cost of capital of the financing of the Project, the period of return on investment (PRI) was of 1.5 years and the cost-benefit ratio was 1.71. The project complied with all economic aspects and its implementation is recommended given the available funds.
dc.formatPDF
dc.languageEspañol
dc.languagees-HN
dc.publisherUniversidad Tecnológica Centroaméricana Unitec
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.sourceUniversidad Tecnológica Centroaméricana UNITEC
dc.subjectPlanta Térmica
dc.subjectVapor
dc.subjectCosto-beneficio
dc.titleAnálisis costo-beneficio en instalación incinerador de lodos para generar vapor plantas térmicas Cortés, Honduras, 2020.
dc.typeTesis
dc.coverageHonduras