dc.contributor | Alicia Reyes Duke | |
dc.creator | Andrés Eduardo Altamirano Ruiz | |
dc.date | 2023-01-06T02:31:29Z | |
dc.date | 2023-01-06T02:31:29Z | |
dc.date | 2020 | |
dc.date | Agosto-2020 | |
dc.date.accessioned | 2023-11-07T20:39:00Z | |
dc.date.available | 2023-11-07T20:39:00Z | |
dc.identifier | https://repositorio.unitec.edu/xmlui/handle/123456789/11388 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/9213256 | |
dc.description | En la zona de Macuelizo, Santa Barbara el 26.59% de la población no tiene acceso a la energía eléctrica. Debido a la falta de conocimientos sobre alternativas viables como los sistemas solares aislados de la red eléctrica, es difícil que el cliente promedio de estas zonas sepa en realidad cuál es su opción más viable para obtener acceso a la energía eléctrica. Es por lo que se hizo un estudio que comparó la viabilidad de un sistema solar fotovoltaico aislado de la red eléctrica versus la extensión de línea de distribución eléctrica primaria para electrificar una residencia de consumo alto en Macuelizo, Santa Bárbara. El estudio se realizó con un enfoque cuantitativo, no experimental, transversal y descriptivo. Se llevó a cabo mediante la comparación de una proyección a 25 años de los Costos Presentes Netos (CPN) de ambos escenarios propuestos. En el primer escenario se diseñó un sistema solar aislado con un generador solar de 11.7 kWp, un banco de baterías de 1255 Ah C100 y dos inversores híbridos de 5 kW cada uno. Del diseño se realizaron simulaciones computacionales en PVSyst y HelioScope. Con estas simulaciones se obtuvieron los resultados promedio de 67.9% de Performance Ratio, 1,338 kWh/kWp de Rendimiento Específico y 15.66 MWh de Generación Anual. El costo inicial requerido calculado fue de $26,565.68 y se proyectó un CPN de -$73,878.60. | |
dc.description | In the area of Macuelizo, Santa Barbara, 26.59% of the population does not have access to electricity. Due to a lack of knowledge about viable alternatives such as off-grid solar systems, it is difficult for the average customer in these areas to really know what their most viable option is to gain access to electricity. That is why a study was carried out that compared the feasibility of a photovoltaic solar system isolated from the electrical network versus the extension of the primary electrical distribution line to electrify a high consumption residence in Macuelizo, Santa Bárbara. The study was carried out with a quantitative, non-experimental, cross-sectional and descriptive approach. It was carried out by comparing a 25-year projection of the Net Present Costs (NPC) of both proposed scenarios. In the first scenario, an isolated solar system was designed with an 11.7 kWp solar generator, a 1255 Ah C100 battery bank and two hybrid inverters of 5 kW each. Computational simulations of the design were carried out in PVSyst and HelioScope. With these simulations, the average results of 67.9% Performance Ratio, 1,338 kWh/kWp of Specific Performance and 15.66 MWh of Annual Generation were obtained. The initial required cost calculated was $26,565.68 and a CPN of -$73,878.60 was projected. | |
dc.format | PDF | |
dc.language | Español | |
dc.language | es-HN | |
dc.publisher | Universidad Tecnológica Centroamericana UNITEC | |
dc.rights | Atribución-NoComercial-SinDerivadas 4.0 Internacional | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es | |
dc.source | Universidad Tecnológica Centroamericana UNITEC | |
dc.subject | Fotovoltaicas | |
dc.subject | Red eléctrica | |
dc.subject | Startups | |
dc.title | Comparación de viabilidad de un sistema solar fotovoltaico aislado de la red eléctrica versus una extensión de línea de distribución eléctrica primaria para una residencia de consumo alto en Macuelizo, Santa Bárbara | |
dc.type | Proyecto de Graduación | |
dc.coverage | Macuelizo, Santa Bárbara | |