dc.creatorCOSTA, PRISCILA
dc.creatorRAELE, MARCUS P.
dc.creatorDOMIENIKAN, CLAUDIO
dc.creatorMADI FILHO, TUFIC
dc.creatorZAHN, GUILHERME S.
dc.creatorGENEZINI, FREDERICO A.
dc.creatorINTERNATIONAL NUCLEAR ATLANTIC CONFERENCE
dc.date2019-12-27T18:44:10Z
dc.date2019-12-27T18:44:10Z
dc.dateOctober 21-25, 2019
dc.date.accessioned2023-09-28T14:13:12Z
dc.date.available2023-09-28T14:13:12Z
dc.identifierhttp://repositorio.ipen.br/handle/123456789/30554
dc.identifier0000-0002-6318-6805
dc.identifier0000-0002-6461-6766
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9000783
dc.descriptionA portable thermal neutron detector prototype, using a PIN-type silicon photodiode coupled to a boron converter, was developed at the Nuclear and Energy Research Institute (IPEN-CNEN/SP). Several boron layers were made by Pulsed Laser Deposition method and two different prototypes were made using distinct approaches in the associated electronics. The prototypes were characterized by measurements with the cold neutron beam at PHADES (Polarized 3He and Detector Experiment Station), in the NIST Center for Neutron Research. The distance between the prototype and the neutron source was different for each prototype: 70 cm (prototype one) and 7 cm (prototype two). The linearity behavior was verified for both prototypes in order to verify the relationship between counts and neutron fluence. The intrinsic efficiency values obtained for prototypes one and two were, respectively, (1.78 ?? 0.01)% and (5.2 ?? 0.4)%. The angular dependence was verified only for prototype one. The concept of this detector can be applied in a future dosimeter project.
dc.descriptionConselho Nacional de Desenvolvimento Cient??fico e Tecnol??gico (CNPq)
dc.descriptionCNPq: 870240/1997-8
dc.format1163-1170
dc.publisherAssocia????o Brasileira de Energia Nuclear
dc.rightsopenAccess
dc.subjectthermal neutrons
dc.subjectphotodiodes
dc.subjectportable equipment
dc.subjectsilicon
dc.subjectcold neutrons
dc.subjectefficiency
dc.subjectneutron detectors
dc.subjectbrazilian cnen
dc.titleCharacterization of a portable thermal neutron detector
dc.typeTexto completo de evento
dc.coverageI