dc.creatorSouza, Maria Verônica de
dc.creatorSouza, Patrícia Coutinho de
dc.creatorRodrigues, Bernardo de Lima
dc.creatorRibeiro Júnior, José Ivo
dc.creatorCordeiro, Rachel Rodrigues
dc.date2018-07-23T10:39:32Z
dc.date2018-07-23T10:39:32Z
dc.date2006-07-05
dc.date.accessioned2023-09-27T22:18:07Z
dc.date.available2023-09-27T22:18:07Z
dc.identifier2177-3491
dc.identifierhttp://www.ceres.ufv.br/ojs/index.php/ceres/article/view/3157
dc.identifierhttp://www.locus.ufv.br/handle/123456789/20669
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8973363
dc.descriptionOs objetivos deste trabalho foram determinar e comparar a concentração do fibrinogênio por duas técnicas distintas em 120 eqüinos clinicamente sadios, da raça Mangalarga Marchador. A concentração do fibrinogênio variou de 200 a 400 mg dL-1 pelo método da precipitação pelo calor e de 129 a 424 mg dL-1 pelo método cronométrico. Embora os métodos utilizados tenham fornecido médias diferentes (p<0,05), os valores obtidos em ambos os casos estiveram entre aqueles considerados normais para a espécie eqüina. Além disso, quando a concentração do fibrinogênio, pelo método de precipitação pelo calor, foi de 200 mg dL-1, pelo método cronométrico a média variou de 140 a 150 mg dL-1. Já quando o valor do fibrinogênio foi de 400 mg dL-1, a variação da média no método cronométrico foi de 280 a 310 mg dL-1.
dc.descriptionThe objective of this work was to determine and to compare the plasma fibrinogen concentration using two different techniques in 120 clinically healthy Mangalarga Marchador horses. The fibrinogen concentration was 200 to 400 mg dL -1 (heat-precipitation method) and 129 to 424 mg dL -1 (chronometric method). Although the methods used resulted in different average values (p<0.05), the values obtained with both methods were among those considered as normal for the equine. Furthermore, when the fibrinogen concentration by the heat-precipitation method was 200 mg dL -1 , in the chronometric method it ranged from 140 mg dL -1 to 150 mg dL -1 . However, when the value was 400 mg dL -1 , the range in the chronometric method was 280 mg dL -1 to 310 mg dL -1 .
dc.formatpdf
dc.formatapplication/pdf
dc.languagepor
dc.publisherRevista Ceres
dc.relationv. 53, n. 307, p. 382-386, maio/ junho 2006
dc.rightsOpen Access
dc.subjectFibrinogênio
dc.subjectEqüinos
dc.subjectCronometria
dc.subjectPrecipitação pelo calor
dc.titleConcentração do fibrinogênio no plasma sanguíneo de equinos da raça Mangalarga marchador por diferentes métodos
dc.typeArtigo


Este ítem pertenece a la siguiente institución