Estimativa da evaporação nos reservatórios de Três Marias – MG e Sobradinho – BA
Três Marias – MG and Sobradinho – BA reservoir evaporation estimates
dc.contributor | Martinez, Mauro Aparecido | |
dc.contributor | http://lattes.cnpq.br/8785400532666567 | |
dc.contributor | Pereira, Silvio Bueno | |
dc.contributor | Silva, Demetrius David da | |
dc.creator | Vieira, Nayara Paula Andrade | |
dc.date | 2016-03-11T17:04:49Z | |
dc.date | 2016-03-11T17:04:49Z | |
dc.date | 2015-02-12 | |
dc.date.accessioned | 2023-09-27T20:57:45Z | |
dc.date.available | 2023-09-27T20:57:45Z | |
dc.identifier | VIEIRA, Nayara Paula Andrade. Estimativa da evaporação nos reservatórios de Três Marias – MG e Sobradinho – BA. 2015. 91f. Dissertação (Mestrado em Engenharia Agrícola) - Universidade Federal de Viçosa, Viçosa. 2015. | |
dc.identifier | http://www.locus.ufv.br/handle/123456789/7335 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8951744 | |
dc.description | A evaporação é um dos principais processos envolvidos no balanço hídrico e de calor. Estudos que possibilitem a obtenção de estimativas precisas de evaporação em reservatórios representam uma importante ação para o adequado gerenciamento e manejo dos recursos hídricos. Dessa forma, objetivou-se estimar a evaporação, a partir da aplicação dos modelos matemáticos Penman, Linacre, Kohler et al., Thornthwaite e Complementary Relationship Lake Evaporation – CRLE e pela metodologia do Tanque Classe A, nos reservatórios de Sobradinho e de Três Marias, localizados no rio São Francisco; e verificar se estações meteorológicas localizadas ao entorno dos reservatórios podem ser utilizadas para predizer a evaporação. Para alcançar os objetivos foram obtidas séries históricas de dados meteorológicos das estações localizadas nos reservatórios e nas cidades vizinhas. Por meio dos modelos Penman, Linacre, Kohler et al., Thornthwaite, CRLE e pelo método do tanque Classe A (com coeficientes de tanque de 0,4, 0,6 e 0,8) foi possível estimar a evaporação nos reservatórios. A comparação entre os modelos foi feita aplicando-se teste “t” ao nível de 5% de probabilidade. Foi realizada análise de sensibilidade dos modelos aos dados meteorológicos de entrada e teste do parâmetro β 1, por meio do teste “t”, para comparar as evaporações estimadas pelas diferentes estações. As lâminas evaporadas foram convertidas em vazão evaporada para verificar a quantidade de água que deixa de passar pelas turbinas geradoras de energia. Os resultados permitiram constatar que: a) a evaporação média anual no reservatório de Sobradinho estimada pelo modelo de Penman foi de 2.108 mm e no reservatório de Três Marias foi de 1.615 mm; b) em relação ao modelo de Penman, o modelo Linacre superestima a evaporação para os dois reservatórios; c) os modelos Kohler et al. e Thornthwaite subestimam a evaporação, em relação a Penman, para os dois reservatórios; d) o único modelo que apresenta sensibilidade à precipitação é Linacre; e) a vazão média decorrente da evaporação para o reservatório de Sobradinho e Três Marias é 203 m3 s-1 e 39 respectivamente, e; f) As estações meteorológicas m3 s-1, localizadas no reservatório, estimam evaporações estatisticamente diferentes daquelas obtidas pelas estações ao entorno dos reservatórios de Sobradinho e Três Marias, com exceção do modelo Kohler et al. em Sobradinho, e do modelo Linacre em Três Marias. | |
dc.description | Evaporation is one of the main processes involved in the water balance and in the thermal stratification in reservoirs. Studies that permit the obtainment of precise reservoir evaporation estimates are important for the correct administration and management of the water resources. Therefore evaporation estimates were made by applying various mathematical models to measure the evaporation of the Sobradinho Reservoir and the Três Marias Reservoir located in the São Francisco River: Penman, Linacre, Kohler et al., Thornthwaite, Complementary Relationship Lake Evaporation – CRLE, and by the Class A pan evaporation methodology. These estimates were also used to verify the evaporation prediction capability of the meteorological stations near the reservoirs. Historical records of meteorological data of these stations were found in the reservoirs and in the nearby cities. By means of the Penman, Linacre, Kohler et al., Thornthwaite, and CRLE models; and the Class A pan methodology (with pan coefficients of 0,4, 0,6, and 0,8) it was possible to estimate the reservoirs' evaporation. The comparison between the models was made by applying the t-test at the significance level of 0.05. The sensitivity analysis of the models to the entered meteorological data and the β parameter estimation, by means of the t-test, were realized to compare the evaporation estimates of the stations. The evaporate depths were converted into evaporated flow to verify the amount of water that does not pass through the power generating turbines. The results allowed for the following to be determined: a) in relation to the Penman model, the annual average evaporation of the Sobradinho Reservoir was of 2.108 mm and of the Três Marias Reservoir was of 1.615 mm; b) in relation to the Penman model, the Linacre model overestimates the evaporation for both of the reservoirs; c) the Kohler et al. and the Thornthwaite models underestimate the evaporation in relation to the Penman model for both of the reservoirs; d) only the Linacre model presents sensitivity to the precipitation; e) the average flow corresponding to the evaporation of the reservoirs are respectively of 203 m3 s-1 and of 39 m3 s-1 for the Sobradinho Reservoir and the Três Marias Reservoir; and f) the meteorological stations located on the lakes estimated evaporation rates statistically different from those obtained from the stations nearby the Sobradinho and the Três Marias lakes, with the exception of the Kohler et al. model in the Sobradinho Reservoir, and the Linacre model in the Três Marias Reservoir. | |
dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior | |
dc.format | application/pdf | |
dc.language | por | |
dc.publisher | Universidade Federal de Viçosa | |
dc.rights | Acesso Aberto | |
dc.subject | Reservatórios | |
dc.subject | Evaporação | |
dc.subject | São Francisco, rio | |
dc.subject | Engenharia Agrícola | |
dc.title | Estimativa da evaporação nos reservatórios de Três Marias – MG e Sobradinho – BA | |
dc.title | Três Marias – MG and Sobradinho – BA reservoir evaporation estimates | |
dc.type | Dissertação |