dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorTonetto, Mateus Rodrigues
dc.creatorPinto, Shelon Cristina Souza
dc.creatorRastelli, Alessandra de Nara Souza
dc.creatorBorges, Alvaro Henrique
dc.creatorSaad, José Roberto Cury
dc.creatorPedro, Fábio Luis Miranda
dc.creatorAndrade, Marcelo Ferrarezi de
dc.creatorBandéca, Matheus Coelho
dc.date2014-05-27T11:27:32Z
dc.date2016-10-25T18:41:40Z
dc.date2014-05-27T11:27:32Z
dc.date2016-10-25T18:41:40Z
dc.date2013-01-01
dc.date.accessioned2017-04-06T02:08:25Z
dc.date.available2017-04-06T02:08:25Z
dc.identifierJournal of Contemporary Dental Practice, v. 14, n. 1, p. 76-79, 2013.
dc.identifier1526-3711
dc.identifierhttp://hdl.handle.net/11449/74305
dc.identifierhttp://acervodigital.unesp.br/handle/11449/74305
dc.identifier10.5005/jp-journals-10024-1274
dc.identifier2-s2.0-84876856243.pdf
dc.identifier2-s2.0-84876856243
dc.identifierhttp://dx.doi.org/10.5005/jp-journals-10024-1274
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/895073
dc.descriptionAims and objectives: The behavior of polymer-matrix composite is dependent on the degree of conversion. The aim of this study was to evaluate the degree of conversion of two resin cements following storage at 37°C immediately, 24 and 48 hours, and 7 days after light-curing by FTIR analysis. Materials and methods: The specimens were made in a metallic mold and cured with blue LED with power density of 500 mW/cm2 for 30 seconds. The specimens were pulverized, pressed with KBr and analyzed with FTIR following storage times. Statistical analysis used: ANOVA (two-way) and Tukey's post hoc. Results: To the polymer-matrix composites between 24 and 48 hours does not show a significant increase (p > 0.05), however, the highest values were found after 7 days. Conclusion: The polymer-matrix composites used in this study showed similarity on the degree of conversion and increased of according to the time of storage.
dc.languageeng
dc.relationJournal of Contemporary Dental Practice
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDegree of conversion
dc.subjectFTIR analysis
dc.subjectPolymers
dc.subject2 hydroxyethyl methacrylate
dc.subject4 methacryloxyethyltrimellitic acid
dc.subject4-methacryloxyethyltrimellitic acid
dc.subjectbisphenol A bis(2 hydroxypropyl) ether dimethacrylate
dc.subjectcarbon
dc.subjectmacrogol derivative
dc.subjectmethacrylic acid derivative
dc.subjectpolymer
dc.subjectpolymethacrylic acid derivative
dc.subjectpolyurethan
dc.subjectresin
dc.subjectresin cement
dc.subjecttricarboxylic acid
dc.subjecttriethylene glycol dimethacrylate
dc.subjecturethane dimethacrylate luting resin
dc.subjectchemistry
dc.subjectclassification
dc.subjectdental bonding
dc.subjectdental curing light
dc.subjecthuman
dc.subjectinfrared spectroscopy
dc.subjectmaterials testing
dc.subjectpolymerization
dc.subjectradiation dose
dc.subjectradiation exposure
dc.subjecttemperature
dc.subjecttight junction
dc.subjecttime
dc.subjectBisphenol A-Glycidyl Methacrylate
dc.subjectCarbon
dc.subjectComposite Resins
dc.subjectCuring Lights, Dental
dc.subjectHumans
dc.subjectLight-Curing of Dental Adhesives
dc.subjectMaterials Testing
dc.subjectMethacrylates
dc.subjectPolyethylene Glycols
dc.subjectPolymerization
dc.subjectPolymethacrylic Acids
dc.subjectPolyurethanes
dc.subjectRadiation Dosage
dc.subjectResin Cements
dc.subjectSelf-Curing of Dental Resins
dc.subjectSpectroscopy, Fourier Transform Infrared
dc.subjectTemperature
dc.subjectTime Factors
dc.subjectTricarboxylic Acids
dc.titleDegree of conversion of polymer-matrix composite assessed by FTIR analysis
dc.typeOtro


Este ítem pertenece a la siguiente institución