dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorRiehl, Rudolf Ribeiro
dc.creatorRuppert Filho, Ernesto
dc.date2014-05-27T11:22:39Z
dc.date2016-10-25T18:24:37Z
dc.date2014-05-27T11:22:39Z
dc.date2016-10-25T18:24:37Z
dc.date2007-12-01
dc.date.accessioned2017-04-06T01:27:40Z
dc.date.available2017-04-06T01:27:40Z
dc.identifierProceeding of International Conference on Electrical Machines and Systems, ICEMS 2007, p. 1244-1248.
dc.identifierhttp://hdl.handle.net/11449/70017
dc.identifierhttp://acervodigital.unesp.br/handle/11449/70017
dc.identifier10.1109/ICEMS.2007.4411988
dc.identifierWOS:000256434000050
dc.identifier2-s2.0-50049134465
dc.identifierhttp://dx.doi.org/10.1109/ICEMS.2007.4411988
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/891178
dc.descriptionThe aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].
dc.languageeng
dc.relationProceeding of International Conference on Electrical Machines and Systems, ICEMS 2007
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectElectromagnetic interference
dc.subjectInduction motor
dc.subjectPspice
dc.subjectPWM inverter
dc.subjectCharacteristic equations
dc.subjectCommon modes
dc.subjectDifferential-mode
dc.subjectElectrical machines
dc.subjectElectro magnetic interferences
dc.subjectEquivalent electrical circuits
dc.subjectHigh frequencies
dc.subjectHigh-frequency induction
dc.subjectInternational conferences
dc.subjectMotor parameters
dc.subjectSimple methods
dc.subjectSimplified method
dc.subjectSystem simulations
dc.subjectThree-phase induction motors
dc.subjectThree-phase inverters
dc.subjectWaveforms
dc.subjectAC motors
dc.subjectDifference equations
dc.subjectElectric drives
dc.subjectElectric network parameters
dc.subjectElectromagnetic compatibility
dc.subjectElectromagnetic pulse
dc.subjectElectromagnetism
dc.subjectInduction motors
dc.subjectParameter estimation
dc.subjectSPICE
dc.subjectVariable speed drives
dc.subjectMotors
dc.titleA simplified method for determining the high frequency induction motor equivalent electrical circuit parameters to be used in EMI effect
dc.typeOtro


Este ítem pertenece a la siguiente institución