Otro
Degree of conversion and molecular weight of one denture base and three reline resins submitted post-polymerization treatments
Registro en:
Materials Research, v. 10, n. 2, p. 191-197, 2007.
1516-1439
10.1590/S1516-14392007000200016
S1516-14392007000200016
2-s2.0-35148875133.pdf
2-s2.0-35148875133
Autor
Urban, Vanessa Migliorini
Machado, Ana Lucia
Vergani, Carlos Eduardo
Jorge, Érica Gouveia
dos Santos, Luís Presley Serejo
Leite, Edson Roberto
Canevarolo, Sebastião Vicente
Resumen
The effect of post-polymerization treatments (MW-microwave irradiatron and WB-water-bath) on the degree of conversion (DC) of three reline resins (Ufi Gel hard-U, Kooliner-K, and Tokuso Rebase Fast-T) and one denture base resin (Lucitone 550-L), submitted to two polymerization cycles (LS-short and LL-long), was evaluated by using FT-Raman spectroscopy (n = 5). The molecular weight (Mw) of the powder of all materials and of K polymerized specimens (control; MW; and WB; n = 3) was analyzed using GPC. DC data were analyzed using Kruskal-Wallis test (α = .05). For control specimens, there were no significant differences between U (68%) and LL (77%) and among LL, K (81%), and T (84%). LS (92%) had the highest DC (P<0.05). Only material K exhibited an increased DC after WB (P<0.05). All powders had Mw from 4.0 × 105 to 6.5 × 105 and narrow Mw distributions (2.1 to 3.6). Polymerization and post-polymerization produced K specimens with Mw similar to that of K powder.