dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorOliveira, Anderson de Souza Castelo
dc.creatorGonçalves, M.
dc.creatorCardozo, A. C.
dc.creatorBarbosa, F. S S
dc.date2014-05-27T11:21:18Z
dc.date2016-10-25T18:20:39Z
dc.date2014-05-27T11:21:18Z
dc.date2016-10-25T18:20:39Z
dc.date2005-04-01
dc.date.accessioned2017-04-06T01:12:57Z
dc.date.available2017-04-06T01:12:57Z
dc.identifierElectromyography and Clinical Neurophysiology, v. 45, n. 3, p. 167-175, 2005.
dc.identifier0301-150X
dc.identifierhttp://hdl.handle.net/11449/68199
dc.identifierhttp://acervodigital.unesp.br/handle/11449/68199
dc.identifier2-s2.0-20744455546
dc.identifier0000-0001-9462-0240
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/889567
dc.descriptionThe purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.
dc.languageeng
dc.relationElectromyography and Clinical Neurophysiology
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBiceps brachii
dc.subjectDynamic contractions
dc.subjectElectromyography fatigue threshold
dc.subjectMuscle fatigue
dc.subjectadult
dc.subjectbiceps brachii muscle
dc.subjectelbow flexion
dc.subjectelectromyogram
dc.subjectelectromyographic fatigue threshold
dc.subjecthuman
dc.subjecthuman experiment
dc.subjectmale
dc.subjectmuscle contraction
dc.subjectmuscle exercise
dc.subjectmuscle fatigue
dc.subjectnormal human
dc.subjectweight bearing
dc.subjectAdult
dc.subjectArm
dc.subjectElectromyography
dc.subjectExercise Tolerance
dc.subjectHumans
dc.subjectIsotonic Contraction
dc.subjectMale
dc.subjectMuscle Fatigue
dc.subjectMuscle, Skeletal
dc.subjectReference Values
dc.subjectWeight Lifting
dc.titleElectromyographic fatigue threshold of the biceps brachii muscle during dynamic contraction
dc.typeOtro