dc.creatorClapis, Franciele C. Meireles
dc.creatorMartins, Maria Auxiliadora
dc.creatorJapur, Camila Cremonezi
dc.creatorMartins Filho, Olindo Assis
dc.creatorÉvora, Paulo Roberto Barbosa
dc.creatorBasile Filho, Aníbal
dc.date2013-09-09T16:29:38Z
dc.date2013-09-09T16:29:38Z
dc.date2010
dc.date.accessioned2023-09-26T23:48:09Z
dc.date.available2023-09-26T23:48:09Z
dc.identifierCLAPIS, Franciele C. et al. Meireles et al. Mechanical ventilation mode (volume × pressure) does not change the variables obtained by indirect calorimetry in critically ill patients. J. Crit. Care., v. 25, n. 4, p. 659.e9–659.e16, Dec. 2010.
dc.identifier0883-9441
dc.identifierhttps://www.arca.fiocruz.br/handle/icict/6860
dc.identifier10.1016/j.jcrc.2009.11.010.
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8894372
dc.descriptionPurpose:The aim of the study was to analyze the difference between the results obtained by indirect calorimetry (IC) using volume-controlled and pressure-controlled mechanical ventilation in 2 different ventilators and to characterize the variables achieved by IC after well-defined changes in minute volume (Vm). Materials and Methods: Prospective study of 20 critically ill patients under volume-controlled (n = 15) or pressure-controlled (n = 5) mechanical ventilation. Three IC measurements of 45 minutes each were taken; values of oxygen consumption (VO2), carbon dioxide production (VCO2), Vm, resting energy expenditure (REE), and respiratory quotient (RQ) were obtained. For the last measurement, Vm was set at 20% above the baseline. Results: There were no differences between the results obtained by IC during volume-controlled and pressure-controlled mechanical ventilation. The most relevant changes in the variables obtained by IC before and after intervention in Vm were a significant increase in VCO2(from 165 to 177 mL•min−1; P b.01), a decrease in PaCO2 (from 38.49 to 28.46 mm Hg;Pb.01), and a rise in pH (from 7.41 to 7.49;Pb.01). There were no alterations in VO2, REE, or RQ. Conclusions: Ventilators and ventilation modes do not influence the IC measurements. The observed changes have no clinical effects and are reversible, provided that increased Vm is maintained for no longer than 45 minutes
dc.formatapplication/pdf
dc.languageeng
dc.publisherElsevier
dc.rightsrestricted access
dc.subjectIndirect calorimetry
dc.subjectMechanical ventilation
dc.subjectICU setting
dc.subjectVO2
dc.subjectVCO2
dc.titleMechanical ventilation mode (volume × pressure) does not change the variables obtained by indirect calorimetry in critically ill patients