Effectiveness of alcohol gel for the disinfection of stethoscopes contaminated with methicillin-resistant Staphylococcus aureus

dc.creatorTeixeira, Arthur Alves
dc.creatorRisola, Bruno Maciel
dc.creatorDias-Netto, Herval Pozzeti
dc.creatorAndrade, Maelcio Silva de
dc.creatorValente, Elisabeth
dc.creatorNielebock, Marco Antonio Prates
dc.creatorSangenis, Luiz Henrique Conde
dc.date2019-04-24T13:55:16Z
dc.date2019-04-24T13:55:16Z
dc.date2016
dc.date.accessioned2023-09-26T23:05:56Z
dc.date.available2023-09-26T23:05:56Z
dc.identifierTEIXEIRA, Arthur Alves et al. Eficácia do álcool gel na desinfecção de estetoscópios contaminados por Staphylococcus aureus resistente à meticilina. Revista de Epidemiologia e Controle de Infecção, v. 5, n. 4, p. 187-190, out./dez. 2015.
dc.identifier2238-3360
dc.identifierhttps://www.arca.fiocruz.br/handle/icict/32709
dc.identifier10.17058/reci.v5i4.6059
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8886817
dc.descriptionJustificativa e Objetivos: Apesar de muito utilizados, pouca atenção tem sido dispensada aos cuidados básicos no manuseio e desinfecção dos estetoscópios. Staphylococcus aureus resistente à meticilina (MRSA) é frequentemente encontrado nestes instrumentos, sendo um grande risco para pacientes hospitalizados. O álcool gel possui propriedades reconhecidamente eficazes para eliminar os microrganismos mais frequentemente envolvidos nas infecções. Esse estudo tem o objetivo de verificar a eficácia do álcool gel na desinfecção dos estetoscópios contaminados por MRSA utilizados pelos profissionais de saúde de um Hospital Universitário do Rio de Janeiro. Métodos: Profissionais de saúde foram selecionados de forma aleatória de agosto a novembro de 2012, sendo coletadas amostras com swab estéril de 105 estetoscópios antes e após a higienização com álcool gel 70% e realizadas culturas e identificação de bactérias. Resultados: A contaminação bacteriana estava presente em 87 (82,85%) estetoscópios analisados, sendo que em 76 (72,38%) foram identificadas bactérias Gram positivas. S. aureus estava presente em 7,61% dos estetoscópios e MRSA em 87,5% destes. Após o uso do álcool gel, houve redução de 71,44% da contaminação bacteriana geral e eliminação de MRSA em 100% dos estetoscópios analisados. Conclusão: Deve-se melhorar o cuidado na higienização dos estetoscópios, pelo risco de carrear bactérias patogênicas envolvidas em infecções hospitalares. O álcool gel mostrou-se adequado para desinfecção de estetoscópios contaminados por MRSA.
dc.descriptionBackground and Objectives: Although very widely used, little attention has been paid to basic care when handling and disinfecting stethoscopes. Methicillin-resistant staphylococcus aureus (MRSA) is often found in these tools, being a great risk for hospitalized patients. Alcohol gel has known effective properties to eliminate the microorganisms most frequently involved in infections. This study aims to verify the effectiveness of alcohol gel for the disinfection of stethoscopes contaminated by MRSA used by health professionals of a university hospital in the city of Rio de Janeiro. Methods: Health professionals were randomly selected from August to November 2012; samples were collected using sterile swabs from 105 stethoscopes, before and after their cleaning with 70% alcohol gel and cultures were performed to identify the bacteria. Results: Bacterial contamination was present in 87 (82.85%) of the analyzed stethoscopes and Gram-positive bacteria were identified in 76 (72.38%) of them. S. aureus was present in 7.61% of stethoscopes and MRSA in 87.5% of them. After the use of alcohol gel, there was a 71.44% overall reduction of bacterial contamination and elimination of MRSA from 100% of the analyzed stethoscopes. Conclusion: The cleaning of stethoscopes should be improved, due to risk of their carrying of pathogenic bacteria involved in hospital infections. Alcohol gel use showed to be adequate for the disinfection of stethoscopes contaminated by MRSA.
dc.formatapplication/pdf
dc.languagepor
dc.publisherNúcleo de Epidemiologia do Hospital Santa Cruz
dc.rightsopen access
dc.subjectEstetoscópios
dc.subjectContaminação
dc.subjectÁlcool etílico
dc.subjectDesinfecção
dc.subjectStaphylococcus aureus resistente à meticilina
dc.subjectStethoscopes
dc.subjectContamination
dc.subjectEthanol
dc.subjectDisinfection
dc.subjectMethicillin-resistant Staphylococcus aureus
dc.titleEficácia do álcool gel na desinfecção de estetoscópios contaminados por Staphylococcus aureus resistente à meticilina
dc.titleEffectiveness of alcohol gel for the disinfection of stethoscopes contaminated with methicillin-resistant Staphylococcus aureus