dc.creatorMohamadain, K. E. M.
dc.creatorAzevedo, A. C. P.
dc.creatorRosa, L. A. R. da
dc.creatorGuebel, M. R. N.
dc.creatorBoechat, M. C. B.
dc.date2013-02-05T16:12:22Z
dc.date2013-02-05T16:12:22Z
dc.date2003
dc.date.accessioned2023-09-26T20:45:37Z
dc.date.available2023-09-26T20:45:37Z
dc.identifierMOHAMADAIN, K. E. M. et al. Dose measurements using thermoluminescent dosimeters and DoseCal software at two paediatric hospitals in Rio de Janeiro. Appl. radiat. isot., Oxford, v. 59, n. p. 53-57, jul. 2003.
dc.identifier10.1016/S0969-8043(03)00122-2
dc.identifierhttps://www.arca.fiocruz.br/handle/icict/6298
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8863380
dc.descriptionA dosimetric survey in paediatric radiology is currently being carried out at the paediatric units of two large hospitals in Rio de Janiero city: IPPMG (Instituto de Pediatria e Puericultura Martagão Gesteira, University Hospital of Federal University of Rio de Janeiro) and IFF (Instituto Fernandes Figueira, FIOCRUZ). Chest X-ray examination doses for AP, PA and LAT projections of paediatric patients have been obtained with thermoluminescent dosimeters (TLDs) and with use of a software package DoseCal. In IPPMG and IFF 100 patients have been evaluated with the use of the TLDs and another group of 100 patients with the DoseCal software. The aim of this work was to estimate the entrance skin dose (ESD) for frontal, back and lateral chest X-rays exposure of paediatric patients. For ESD evaluation, three different TL dosimeters have been used, namely LIF:Mg,Ti (TLD100), CaSO4:Dy and LiF:Mg,Cu,P (TLD100H). The age intervals considered were 0-1, 1-5, 5-10 and 10-15 years. The results obtained with all dosimeters are similar, and it is in good agreement with the DoseCal software, especially for AP and PA projections. However, some larger discrepancies are presented for the LAT projection.
dc.formatapplication/pdf
dc.languageeng
dc.publisherPergamon Press
dc.relationCOR NRPB, 1992. Institute of Physical Science in Medicine and Dosimetry. Working Party National Protocol for Dose Measurements in Diagnostic Radiology. IPS, New York.
dc.relationEURATOM, 1997. Council Directive 971341/EURATOM. Off. J. Eur. Communities (L180) 1, 22–27.
dc.relationFendel, H., Schneider, K., Sch. ofer, H., Bakowski, C., Kohn, M.M., 1985. Optimisation in paediatric radiology: are there specific problems for quality assurance in paediatric radiology? In: Moores, B.M. et al. (Eds.), Technical and Physical Parameters for Quality Assurance in Medical Diagnostic Radiology: Tolerances, Limiting Values and Appropriate Measuring Methods. BIR 18, British Institute of Radiology, London, pp. 159–165.
dc.relationFendel, H., Schneider, K., Sch. ofer, H., Bakowski, C., Kohn, M.M., 1985. Optimisation in paediatric radiology: are there specific problems for quality assurance in paediatric radiology? In: Moores, B.M. et al. (Eds.), Technical and Physical Parameters for Quality Assurance in Medical Diagnostic Radiology: Tolerances, Limiting Values and Appropriate Measuring Methods. BIR 18, British Institute of Radiology, London, pp. 159–165.
dc.relationNRPB, 1993. National Radiological Protection Board Occupational Public and medical exposure. Documents of NRPB, Vol. 4, No. 2. UK National Radiological Protection Board, Chilton.
dc.relationPortaria, 1998. Diretrizes de Prote@*ao Radiol!ogica em Radiodiagn! ostico M!edico Odontol! ogico, Portaria 453 do Minist!erio da Sa! ude, D O U 103, 01/06/98.
dc.rightsrestricted access
dc.subjectTLD
dc.subjectEntrance Skin Dose
dc.subjectPaediatric Examinations
dc.subjectDoseCal
dc.subjectDosimetria Termoluminescente
dc.subjectMonitoramento de Radiação
dc.subjectRadiografia Torácica
dc.subjectRecém-Nascido
dc.titleDose measurements using thermoluminescent dosimeters and DoseCal software at two paediatric hospitals in Rio de Janeiro