Test-retest reliability of the Work Ability Index (WAI) in nursing workers

dc.creatorSilva Junior, Sérgio Henrique Almeida da
dc.creatorVasconcelos, Ana Glória Godoi
dc.creatorGriep, Rosane Harter
dc.creatorRotenberg, Lúcia
dc.date2015-10-07T18:53:18Z
dc.date2015-10-07T18:53:18Z
dc.date2013
dc.date.accessioned2023-09-26T20:22:43Z
dc.date.available2023-09-26T20:22:43Z
dc.identifierSILVA JUNIOR, Sérgio Henrique Almeida da; et al. Confiabilidade teste-reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem. Rev. Bras. Epidemiol., v.16, n.1, p. 202-209, 2013.
dc.identifier1415-790X
dc.identifierhttps://www.arca.fiocruz.br/handle/icict/11913
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8855551
dc.descriptionEste artigo avalia a confiabilidade teste- -reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem. Foi aplicado questionário autopreenchível duas vezes a um grupo de 80 trabalhadores de enfermagem (enfermeiros, técnicos e auxiliares de enfermagem) de um hospital público no Município do Rio de Janeiro, com intervalo entre sete e quinze dias. A confiabilidade foi estimada pela estatística kappa ponderada quadrática, pelo coeficiente de correlação intraclasse (CCI) e pelo gráfico de Bland e Altman. Dos participantes, 81% eram mulheres e com idade variando de 22 a 67 anos (média = 39,1; DP = 10,8anos) e 36,3% tinham ensino superior completo. O escore global do ICT apresentou CCI = 0,79 (IC95% 0,67 a 0,86) e kappa = 0,69 (IC95% 0,50 a 0,80) para o ICT categórico (classificado em baixo, moderado, bom e ótimo). O kappa dos itens do ICT variou de 0,39 a 0,82 e o gráfico de Bland e Altman não mostrou um padrão sistemático. A concordância entre as medidas de teste-reteste indica grau aceitável de confiabilidade, sugerindo adequação do processo de aferição entre trabalhadores de enfermagem.
dc.descriptionThis paper assesses the test retest reliability of the Work Ability Index (WAI) in nursing workers. A self-administered questionnaire was applied twice to a group of 80 workers (nurses and nursing aides/assistants) at a public hospital in Rio de Janeiro, Brazil within an interval from seven to fifteen days. The reliability was estimated using quadratic weighted kappa statistics, interclass correlation coefficient (ICC) and the Bland and Altman plot. Eighty-one percent of participants were women aged betweenfrom 22 to 67 years (mean =39.1; SD=10.8 years); 36.3% had completed higher education. The global score of the WAI presented ICC= 0.79 (IC95% 0.67 to 0.86) and weighted kappa=0.69 (CI95% 0.50 to 0.80) for categorical WAI (classified as low, moderate, good and excellent). The quadratic weighted kappaof the WAI items ranged from 0.39 to 0.82 and the Bland and Altman plot did not show a systematic pattern. The agreement between the test and retest measures shows an acceptable degree of reliability, suggesting the adequacy of the assessment process among nursing workers.
dc.formatapplication/pdf
dc.languagepor
dc.publisherAssociação Brasileira de Pós-Graduação em Saúde Coletiva
dc.rightsopen access
dc.subjectConfiabilidade
dc.subjectCapacidade para o trabalho
dc.subjectEnfermagem
dc.subjectKappa
dc.subjectCoeficiente de Correlação Intraclasse
dc.subjectGráfico de Bland e Altman
dc.subjectReliability
dc.subjectWork ability
dc.subjectNursing
dc.subjectKappa
dc.subjectInterclass Correlation Coefficient (ICC)
dc.subjectBland and Altman graphic
dc.titleConfiabilidade teste-reteste do Índice de Capacidade para o Trabalho (ICT) em trabalhadores de enfermagem
dc.titleTest-retest reliability of the Work Ability Index (WAI) in nursing workers
dc.typeArticle


Este ítem pertenece a la siguiente institución