dc.contributor | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.contributor | Georgia Regents University | |
dc.creator | Carvalho, Adriana Oliveira | |
dc.creator | Ayres, Ana Paulaalmeida | |
dc.creator | Almeida, LetÍcia Cunhaamaral Gonzaga de [UNESP] | |
dc.creator | Briso, André Luiz Fraga [UNESP] | |
dc.creator | Rueggeberg, Frederick Allen | |
dc.creator | Giannini, Marcelo | |
dc.date | 2016-01-28T16:55:27Z | |
dc.date | 2016-01-28T16:55:27Z | |
dc.date | 2015 | |
dc.date.accessioned | 2023-09-12T08:11:44Z | |
dc.date.available | 2023-09-12T08:11:44Z | |
dc.identifier | http://dx.doi.org/10.4103/1305-7456.156845 | |
dc.identifier | European Journal of Dentistry, v. 9, n. 2, p. 246-250, 2015. | |
dc.identifier | 1305-7456 | |
dc.identifier | http://hdl.handle.net/11449/133518 | |
dc.identifier | 10.4103/1305-7456.156845 | |
dc.identifier | 5761956467234702 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8782774 | |
dc.description | Objective: This study evaluated the effects of carbamide peroxide and hydrogen peroxide on the biaxial flexural strength and flexural modulus of bovine dentin. Materials and Methods: Thirty coronal dentin disks (0.5 mm thick × 6.0 mm diameter) were prepared from bovine teeth. The disks were randomly divided into three groups (n=10): A control group (unbleached), a group bleached with 10% carbamide peroxide (8 h at 37°C), and a group bleached with 38% hydrogen peroxide (three 10 min applications at 37°C). The specimens were tested in a biaxial flexural apparatus held in a universal testing machine at 1.27 mm/min until failure occurred, and the biaxial mechanical properties were calculated. For each test parameter, the data were statistically analyzed by Fisher's PLSD test (predetermined a = 0.05). Results: The group bleached with 38% hydrogen peroxide demonstrated significantly lower flexural strength than the unbleached control group. Hydrogen peroxide treatment resulted in a significantly lower flexural modulus compared with the control group and with carbamide peroxide bleaching. Conclusion: Exposure of dentin to hydrogen peroxide significantly reduced both the flexural strength and the flexural modulus compared with the no-treatment control, whereas exposure to carbamide peroxide did not significantly affect either parameter. | |
dc.description | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description | Fundação Amparo à Pesquisa Estado de São Paulo (FAPESP) | |
dc.description | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Restauradora, Faculdade de Odontologia de Araçatuba, Aracatuba, Rua José Bonifácio, 1193, Vila Mendonça, CEP 16015-050, SP, Brasil | |
dc.description | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Odontologia Restauradora, Faculdade de Odontologia de Araçatuba, Aracatuba, Rua José Bonifácio, 1193, Vila Mendonça, CEP 16015-050, SP, Brasil | |
dc.description | CAPES: 3110/2010 | |
dc.description | CNPq: 305777/2010-6 | |
dc.format | 246-250 | |
dc.language | eng | |
dc.relation | European Journal of Dentistry | |
dc.relation | 0,749 | |
dc.rights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.subject | Biaxial flexural strength | |
dc.subject | Bleaching | |
dc.subject | Carbamide peroxide | |
dc.subject | Dentin | |
dc.subject | Flexural modulus | |
dc.subject | Hydrogen peroxide | |
dc.title | Effect of peroxide bleaching on the biaxial flexural strength and modulus of bovine dentin | |
dc.type | Artigo | |