dc.contributor | University of Wisconsin - la Crosse | |
dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.contributor | National Institute of Standards and Technology | |
dc.creator | Hockel, H. | |
dc.creator | Lauters, M. | |
dc.creator | Jackson, M. | |
dc.creator | Moraes, João Carlos Silos [UNESP] | |
dc.creator | Allen, M. D. | |
dc.creator | Evenson, K. M. | |
dc.date | 2014-05-27T11:20:19Z | |
dc.date | 2014-05-27T11:20:19Z | |
dc.date | 2001-11-12 | |
dc.date.accessioned | 2023-09-12T07:18:31Z | |
dc.date.available | 2023-09-12T07:18:31Z | |
dc.identifier | http://dx.doi.org/10.1007/s003400100643 | |
dc.identifier | Applied Physics B: Lasers and Optics, v. 73, n. 3, p. 257-260, 2001. | |
dc.identifier | 0946-2171 | |
dc.identifier | http://hdl.handle.net/11449/66615 | |
dc.identifier | 10.1007/s003400100643 | |
dc.identifier | WOS:000171819500013 | |
dc.identifier | 2-s2.0-0034767067 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8779848 | |
dc.description | A three-laser heterodyne system was used to measure the frequencies of twelve optically pumped laser emissions from 13CH3OH in the far-infrared (FIR) region. These emissions, ranging from 54 to 142 μm, are reported with fractional uncertainties up to ±2 × 10-7 along with their polarization relative to the CO2 pump. Using the 9P32 and 10R14 CO2 lines, complete spectroscopic assignments for two laser systems were confirmed. | |
dc.description | Department of Physics University of Wisconsin - la Crosse, La Crosse, WI 54601 | |
dc.description | Departamento de Física e Química UNESP, 15385-000 Ilha Solteira - Sao Paulo | |
dc.description | Time and Frequency Division, 847.00 National Institute of Standards and Technology, 325 Broadway, Boulder, CO 80303 | |
dc.description | Departamento de Física e Química UNESP, 15385-000 Ilha Solteira - Sao Paulo | |
dc.format | 257-260 | |
dc.language | eng | |
dc.publisher | Springer | |
dc.relation | Applied Physics B: Lasers and Optics | |
dc.relation | 1.881 | |
dc.relation | 0,740 | |
dc.rights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Carbon dioxide lasers | |
dc.subject | Fourier transform infrared spectroscopy | |
dc.subject | Infrared radiation | |
dc.subject | Light emission | |
dc.subject | Light polarization | |
dc.subject | Methanol | |
dc.subject | Spectroscopic analysis | |
dc.subject | Far infrared region | |
dc.subject | Llasere frequency measurements | |
dc.subject | Optically pumped laser emissions | |
dc.subject | Three laser heterodyne system | |
dc.subject | Optically pumped lasers | |
dc.title | Laser frequency measurements and spectroscopic assignments of optically pumped 13CH3OH | |
dc.type | Artigo | |