| dc.contributor | Universidade Estadual Paulista (Unesp) | |
| dc.contributor | Universidade de São Paulo (USP) | |
| dc.creator | Chopra, Shilpi | |
| dc.creator | Lima Gomes, Paulo Clairmont Feitosa de [UNESP] | |
| dc.creator | Dhandapani, Ramkumar | |
| dc.creator | Snow, Nicholas H. | |
| dc.date | 2015-05-15T13:30:23Z | |
| dc.date | 2015-05-15T13:30:23Z | |
| dc.date | 2014 | |
| dc.date.accessioned | 2023-09-12T05:02:56Z | |
| dc.date.available | 2023-09-12T05:02:56Z | |
| dc.identifier | http://www.scientiachromatographica.com/doi/10.4322/sc.2014.024 | |
| dc.identifier | Scientia Chromatographica, v. 6, n. 2, p. 105-116, 2014. | |
| dc.identifier | 1984-4433 | |
| dc.identifier | http://hdl.handle.net/11449/123538 | |
| dc.identifier | 10.4322/sc.2014.024 | |
| dc.identifier | 49857977635051 | |
| dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8772974 | |
| dc.description | Direct immersion SPME-GC-MS-MS was used for the analysis of steroids in water at part-per-trillion(ppt) and lower concentrations. The method was validated and extended to real sample analysis. The method were linear from 0.01 to 5 ng/ml with precision less than 10% relative standard deviation for a steroid mixture at 1 ng/ml. Limit of quantitation and limit of detection was found to be 200- 1200 pg/L and 30-200 pg/L respectively and recoveries ranged from 88-103 %. To understand the extraction efficiency of the fiber, a depletion study was performed. The fiber/ sample partition coefficients for the steroids were determined to be 1.0 x 104 to 1.5 x 104 . The extraction was performed without derivatization or the use of an internal standard. SPMEGC-MS-MS effectively demonstrated ultra-trace level detection of steroids in water. | |
| dc.description | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | |
| dc.description | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | |
| dc.format | 105-116 | |
| dc.language | por | |
| dc.relation | Scientia Chromatographica | |
| dc.rights | Acesso restrito | |
| dc.source | Currículo Lattes | |
| dc.subject | Steroids using Solid Phase Microextraction | |
| dc.subject | SPME | |
| dc.subject | Gas Chromatography-Mass Spectrometry-Mass Spectrometry | |
| dc.subject | GC-MS-MS | |
| dc.subject | SPMEGC-MS-MS | |
| dc.subject | water analysis | |
| dc.title | Analysis of Steroids using Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry-Mass Spectrometry (SPME-GC-MS-MS) | |
| dc.type | Artigo | |