dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorChristovão, F.G.
dc.creatorBarros, R.M.L.
dc.creatorFreitas, E.V.V.
dc.creatorLacerda-Neto, J.C.
dc.creatorQueiroz-Neto, A.
dc.date2014-05-20T15:13:03Z
dc.date2016-10-25T17:47:04Z
dc.date2014-05-20T15:13:03Z
dc.date2016-10-25T17:47:04Z
dc.date2007-08-01
dc.date.accessioned2017-04-05T22:58:52Z
dc.date.available2017-04-05T22:58:52Z
dc.identifierArquivo Brasileiro de Medicina Veterinária e Zootecnia. Universidade Federal de Minas Gerais, Escola de Veterinária, v. 59, n. 4, p. 862-868, 2007.
dc.identifier0102-0935
dc.identifierhttp://hdl.handle.net/11449/28624
dc.identifierhttp://acervodigital.unesp.br/handle/11449/28624
dc.identifier10.1590/S0102-09352007000400007
dc.identifierS0102-09352007000400007
dc.identifierS0102-09352007000400007.pdf
dc.identifierhttp://dx.doi.org/10.1590/S0102-09352007000400007
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/873307
dc.descriptionAdaptou-se uma metodologia utilizada no estudo do movimento humano para analisar o movimento de eqüinos em esteira rolante de alto desempenho, construindo-se um sistema de calibração utilizando-se um teodolito eletrônico de alta precisão e calibradores que demarcavam o espaço ocupado pelo animal. Dessa forma, foram obtidas as coordenadas espaciais dos marcadores presentes nos calibradores, compondo o arquivo de calibração. Duas câmeras de vídeo (60Hz) foram posicionadas em vista lateral esquerda, distantes 5m da manta de rolagem da esteira a 1,8m de altura. As imagens foram enquadradas utilizando-se um monitor de vídeo. Para a validação do método, um membro da equipe movimentou, no espaço calibrado, uma haste rígida com marcadores fixados nas suas extremidades, distantes um do outro 43,8cm. Para a análise das imagens, utilizou-se o programa Dvideow, desenvolvido pelo Laboratório de Instrumentação para Biomecânica - UNICAMP. Após a reconstrução tridimensional das imagens utilizou-se um programa matemático para o cálculo do valor médio da distância entre os marcadores. Obteve-se, após a mensuração em 100 quadros, o valor médio de 43,7cm com coeficiente de variação de 0,8%. Estes resultados mostram que a metodologia desenvolvida é precisa e adequada para o estudo da locomoção de eqüinos.
dc.descriptionA methodology used for the study of human movement was adapted to analyze the movement of equines in a high performance treadmill. An electronic high precision theodolite was used to construct a calibration system to demarcate the volume occupied by the animal. It was taken the three dimensions coordinates of each marker present in the calibrator, composing the calibration archive. Two video cameras (60 Hz) were located approximately 5m from the left lateral side of the treadmill at 1.8m height. The images had been fit using a video monitor. For the validation of the method, a member of the team moved into the calibrated space, a 43.8cm long rigid stick with markers settled in its extremities. For the analysis of the images, the Dvideow program developed by the Laboratório de Instrumentação para Biomecânica - UNICAMP was used. After the three-dimensional reconstruction of the images, the calculation of the distance between the markers of the stick was done in 100 frames. The mean was 43.7 cm with a variation coefficient of 0.8%. These results confirm that this methodology is precise and adequate for the study of the locomotion in horses.
dc.languagepor
dc.publisherUniversidade Federal de Minas Gerais (UFMG), Escola de Veterinária
dc.relationArquivo Brasileiro de Medicina Veterinária e Zootecnia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcinematography
dc.subjectthree-dimensional analysis
dc.subjectmovement
dc.subjectEquine
dc.subjectTreadmill
dc.subjectEquino
dc.subjectcinematografia
dc.subjectanálise tridimensional
dc.subjectmovimento
dc.subjectEsteira rolante
dc.titleAnálise cinemática tridimensional do movimento de eqüinos em esteira rolante
dc.typeOtro


Este ítem pertenece a la siguiente institución