dc.contributor | Osma Cruz, Johann Faccelo | |
dc.contributor | Aroca Cervantes, Miguel Ángel | |
dc.contributor | Segura Quijano, Fredy Enrique | |
dc.contributor | Cruz Jiménez, Juan Carlos | |
dc.contributor | Biomicrosystems | |
dc.creator | Merchan Salamanca, Joseph Esteban | |
dc.date.accessioned | 2023-07-14T18:31:51Z | |
dc.date.accessioned | 2023-09-07T01:31:56Z | |
dc.date.available | 2023-07-14T18:31:51Z | |
dc.date.available | 2023-09-07T01:31:56Z | |
dc.date.created | 2023-07-14T18:31:51Z | |
dc.date.issued | 2022-08-19 | |
dc.identifier | http://hdl.handle.net/1992/68455 | |
dc.identifier | instname:Universidad de los Andes | |
dc.identifier | reponame:Repositorio Institucional Séneca | |
dc.identifier | repourl:https://repositorio.uniandes.edu.co/ | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8728438 | |
dc.description.abstract | En este documento queda evidenciado como la electromiografía de superficie puede ser usada con sudor artificial como agente conductor para extraer las señales eléctricas producidas por las unidades motoras del músculo. Con el fin de realizar estas medidas fue diseñado y fabricado un dispositivo vestible de electromiografía para deportistas, con visualización en tiempo real de los datos tomados en el bíceps. Para ello fue necesario crear una aplicación móvil con el fin de poder realizar la visualización de los datos tomados por el microcontrolador desde un teléfono inteligente. Esta comunicación entre el dispositivo y la aplicación móvil es por medio del protocolo Bluetooth Low Energy (BLE), debido a que este protocolo de comunicación es confiable y maneja baja potencia para enviar y recibir datos. A su vez se desarrollan pruebas de funcionamiento con y sin gel conductor, con el fin de corroborar el correcto funcionamiento del dispositivo de electromiografía desarrollado y observar como el sudor artificial puede ser un posible sustituto del gel conductor comercial como agente conductor. Los resultados del estudio muestran señales en un rango de -1.8mv a 1.8mV en el bíceps en los tres tipos de medida. La variación entre los resultados con conductor comercial y con sudor artificial es de 0,006mV lo que representa un cambio de menos del 10%. | |
dc.language | spa | |
dc.publisher | Universidad de los Andes | |
dc.publisher | Maestría en Ingeniería Electrónica y de Computadores | |
dc.publisher | Facultad de Ingeniería | |
dc.publisher | Departamento de Ingeniería Eléctrica y Electrónica | |
dc.relation | A. Gómez and S. Carrillo, "Guía neurológica 7 indicaciones y protocolos básicos indicaciones, protocolos básicos mínimos y requerimientos técnicos: Neurografía y electromiografía," | |
dc.relation | M. Cordeiro, H. Peinado, M. T. Montes, and E. Valverde, "Evaluation of the suitability and clinical applicability of different electrodes for aeeg/ceeg monitoring in the extremely premature infant," Anales de Pediatría, vol. 95, pp. 423-430, 12 2021. | |
dc.relation | "Electromiografía: Medlineplus enciclopedia médica." | |
dc.relation | N. Massó, F. Rey, D. Romero, G. Gual, and G. A. Costa Ll, "Aplicaciones de la electromiografía de superficie en el deporte. apunts med esport. 2010 [citado 16 feb 2016]; 45 (166): 127-136." | |
dc.relation | C. A. E. Muñoz, "Electromiografía de superficie como método para el estudio de la transición aeróbica anaeróbica," Ergonomía, Investigación y Desarrollo, vol. 1, no. 1, pp. 63-80, 2019. | |
dc.relation | F. J. Juan-García, "Utilidad de la electromiografía de superficie en rehabilitación," 2017. | |
dc.relation | S. Ponce N. M. López, D. Piccinini, and M. Roberti, "Desarrollo de un sistema vestible de medición de variables fisiológicas emotion recognition for susceptible communities view project," 2016. | |
dc.relation | "Ad8232 ecg módulo monitor de pulso cardiaco - unit electronics." | |
dc.relation | "Cómo funciona bluetooth low energy: el protocolo estrella de iot - welivesecurity." | |
dc.relation | "Mit app inventor - explore mit app inventor." | |
dc.relation | A. Salim and S. Lim, "Recent advances in noninvasive flexible and wearable wireless biosensors," Biosensors and Bioelectronics, vol. 141, p. 111422, 2019. | |
dc.relation | I. P. Of and C. J. D. Luca, "Imaging the behavior of motor units by decomposition of the emg signal," | |
dc.relation | G. Biagetti, P. Crippa, L. Falaschetti, and C. Turchetti, "Classifier level fusion of accelerometer and semg signals for automatic fitness activity diarization," Sensors, vol. 18, no. 9, 2018. | |
dc.relation | D. Ordóñez-Camacho, E. Gómez, and H. Ávalos, "Tamaño óptimo de la ventana en un filtro de media móvil para rssi: mejorando la estimación de la distancia con bluetooth," in Congreso de Ciencia y Tecnología ESPE, vol. 13, 2018 | |
dc.relation | E. Guzmán-Muñoz and G. Méndez-Rebolledo, "Electromiografía en las ciencias de la rehabilitación," Revista Salud Uninorte, vol. 34, no. 3, pp. 753-765, 2018. | |
dc.relation | Q. Yang, G. Rosati, V. Abarintos, M. A. Aroca, J. F. Osma, and A. Merkoc i, "Wearable and fully printed microfluidic nanosensor for sweat rate, conductivity, and copper detection with healthcare applications," Biosensors and Bioelectronics, vol. 202, p. 114005, 2022. | |
dc.relation | R. R. Silva, P. A. Raymundo-Pereira, A. M. Campos, D. Wilson, C. G. Otoni, H. S. Barud, C. A. Costa, R. R. Domeneguetti, D. T. Balogh, S. J. Ribeiro, et al., "Microbial nanocellulose adherent to human skin used in electrochemical sensors to detect metal ions and biomarkers in sweat," Talanta, vol. 218, p. 121153, 2020 | |
dc.relation | R. N. Khushaba, A. Al-Timemy, S. Kodagoda, and K. Nazarpour, "Combined influence of forearm orientation and muscular contraction on emg pattern recognition," Expert Systems with Applications, vol. 61, pp. 154-161, 2016. | |
dc.relation | J. A. Domínguez Jiménez, "Análisis de las señales emg de superficie del bíceps durante la ejecución de ejercicios con pesas," 2015.. | |
dc.relation | Ad8232 datasheet(pdf) - analog devices. | |
dc.relation | M. Cioni, "A kinesiological and electromyographic analysis of stair descent of individuals with down syndrome and Parkinson's disease," 1998. | |
dc.relation | "El 76% de los colombianos ha sufrido de dolores musculares - acis." | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | |
dc.rights | https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.title | Dispositivo vestible de baja potencia para electromiografía de superficie basada en télefonos inteligentes | |
dc.type | Trabajo de grado - Maestría | |