dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorRodrigues, Letícia Norma Carpentieri
dc.creatorFerreira, Valdir de Souza
dc.creatorZanoni, Maria Valnice Boldrin
dc.date2014-05-20T14:19:39Z
dc.date2016-10-25T17:41:11Z
dc.date2014-05-20T14:19:39Z
dc.date2016-10-25T17:41:11Z
dc.date1998-01-01
dc.date.accessioned2017-04-05T22:31:57Z
dc.date.available2017-04-05T22:31:57Z
dc.identifierEclética Química. Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP, v. 23, p. 123-134, 1998.
dc.identifier0100-4670
dc.identifierhttp://hdl.handle.net/11449/25918
dc.identifierhttp://acervodigital.unesp.br/handle/11449/25918
dc.identifier10.1590/S0100-46701998000100011
dc.identifierS0100-46701998000100011
dc.identifier0000-0002-2296-1393
dc.identifierhttp://dx.doi.org/10.1590/S0100-46701998000100011
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/870749
dc.descriptionVoltamogramas de redissolução catódica de cefaloglicina em meio ácido exibem uma única onda de redução em potenciais próximos da descarga do eletrólito (-1.0 V). Entretanto, o fármaco pode ser determinado indiretamente em meio alcalino (pH 10) através do complexo formado entre cefaloglicina e Hg(I) gerado na superfície do eletrodo sob potencial de acúmulo positivo (Eac= +0.20 V). Uma curva de calibração linear no intervalo de 0.122 a 1.22 mg/mL foi obtida para cefaloglicina em tampão B-R pH 10 utilizando-se tempo de acúmulo de 30 seg e potencial de acúmulo de +0.20 V. O método mostra alta reprodutibilidade e sensibilidade com desvio padrão relativo de 1,4 % para 5 determinações de 5x10-7 mol/L de cefaclor e limite de detecção de 5,17 ng/mL.
dc.descriptionCephaloglycin in B-R buffer pH < 4 is reduced at HMDE very close to the electrolyte discharge (-1.0 V). Nevertheless, in alkaline medium (pH 10) a peak at -0.6V is observed when cephaloglycin is accumulated at accumulation potentials close to +0.20V by formation of an adsorbed mercury complex. The accumulation of this complex is recommended for use in the indirect determination of cephaloglycin by cathodic stripping voltammetry in the range 0.122 to 1.22 mg/mL with pre-concentration for 30 sec at accumulation potential of +0.20V. The detection limit was calculated to be 5,17 ng/mL (n= 3). The relative standard deviation determined from five determinations at the 5x10-7 mol/L level was 1.4 %.
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.languagepor
dc.publisherEditora Unesp
dc.relationEclética Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectcefaloglicina
dc.subjectcefalosporinas
dc.subjectvoltametria de redissolução catódica
dc.subjectCephaloglycin
dc.subjectcephalosporins
dc.subjectcathodic stripping voltammetry
dc.titleEstudo voltamétrico de redissolução catódica de cefaloglicina em meio aquoso sobre eletrodo de mercúrio
dc.typeOtro


Este ítem pertenece a la siguiente institución