dc.contributor | Grupo de Investigación Estructuras y Materiales - Gimeci | |
dc.creator | Collazos Bolaños, Dennis Alexánder | |
dc.creator | Torres Castellanos, Nancy | |
dc.date.accessioned | 2023-07-29T14:37:17Z | |
dc.date.accessioned | 2023-09-06T21:17:24Z | |
dc.date.available | 2023-07-29T14:37:17Z | |
dc.date.available | 2023-09-06T21:17:24Z | |
dc.date.created | 2023-07-29T14:37:17Z | |
dc.date.issued | 2017 | |
dc.identifier | 0121-5132 | |
dc.identifier | https://repositorio.escuelaing.edu.co/handle/001/2527 | |
dc.identifier | https://www.escuelaing.edu.co/es/investigacion-e-innovacion/editorial/ | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8707314 | |
dc.description.abstract | La contracción plástica del concreto a causa de la rápida evaporación del agua en estado fresco puede generar fisuras que afectan la estética, funcionalidad, resistencia y durabilidad de elementos de concreto, en particular de aquellos que tienen una gran superficie expuesta y un volumen relativamente bajo como losas de pavimentos o pisos; esta fisuración y la posterior reparación generan costos económicos y ambientales adicionales. Uno de los factores que más inciden en la fisuración por contracción plástica es la velocidad del viento, porque promueve altas tasas de evaporación del agua en la superficie del concreto. Se hizo un estudio para determinar el porcentaje óptimo de microfibra de nailon para el control de la fisuración por contracción plástica en losas de concreto, usando agregados reciclados provenientes de residuos de construcción y demolición en diferentes porcentajes de remplazo del agregado grueso. Se elaboraron losas de 100 x 60 cm, con espesor de 8 cm y relación agua-cemento 0,50. Estas losas fueron sometidas a velocidades de viento de 8, 18 y 30 km/h, con medición de temperatura y humedad relativa en el laboratorio. | |
dc.description.abstract | Plastic contraction of concrete, due to quick water evaporation in fresh state, can generate fissures affecting aesthetics, functionality, resistance, and durability of concrete elements, especially those which have a large exposed surface and a relatively small volume such as pavement plates or floors; this fissuration and eventual reparation generate additional
economic and environmental costs. One of the factors that play a bigger role in fissuration for plastic contraction is wind speed, because it fosters high water evaporation rates on the concrete’s surface. A study was performed to determine the optimal percentage of nylon microfiber to control fissuration for
plastic contraction in concrete plates was performed, using recycled aggregates from construction and demolition waste at different ratios replacing coarse aggregates. 100 cm x 60 cm x 8 cm plates were built with a water-cement ratio of 0.50. These plates were exposed to 8, 18, and 30 km/h, measuring temperature and relative humidity in the lab | |
dc.language | spa | |
dc.publisher | Universidad Escuela Colombiana de Ingeniería Julio Garavito | |
dc.publisher | Bogotá | |
dc.relation | 79 | |
dc.relation | 107 | |
dc.relation | 71 | |
dc.relation | N/A | |
dc.relation | Revista de la Escuela Colombiana de Ingeniería | |
dc.relation | Natalani, M.B., Klees, D.R. & Tirner (2000). | |
dc.relation | Shaeles, C.A. & Hover, K.C. (s.f.). Influence of mix proportions and construction operations on plastic shrinkage cracking in thin slabs. ACI Mater J. | |
dc.relation | ACI Committee 305 (1991). Hot weather concreting (ACI 305.R-91). American Concrete Institute, Farmington Hills, 20 pp. | |
dc.relation | Kraai, P.P. (1985). A proposed test to determine the cracking potential due to drying shrinkage of concrete. Concr Construct, 30(9):775-8. | |
dc.relation | Rodríguez & Montardo, 2002. Como se cita en el documento La influencia de fibras sintéticas en las propiedades de hormigones frescos, de la revista Ingeniería de Construcción (20, abril de 2015). Ruiz Sibaja, A., López Ríos, J. & Martínez Jiménez, J. | |
dc.relation | Comité ACI 224 (2001). Control de la fisuración en estructuras de concreto. American Concrete Institute. | |
dc.relation | Soroushian, P., Mirza, F. & Alhozaimy, A. (1995). Plastic shrinkage cracking of polypropylene fiber reinforced concrete. ACI Mater J, 92(5):553-560. | |
dc.relation | Naaman, A.E., Wongtanakitcharoen. T. & Hauser, G. (2005). Influence of different fibers on plastic shrinkage cracking of concrete. ACI Mater J,102(1):49-58. | |
dc.relation | Gluzhge, P.J. (1946). El trabajo del Instituto Científico de Investigación c. Gidrotekhnicheskoye Stroitel’stvo, 4:27-28 [en ruso]. | |
dc.relation | Nixon, P.J. (1976). Reciclado agregado del hormigón es un hormigón. Una revisión. 37-DRC comité, pp. 317-318. | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.source | https://www.escuelaing.edu.co/es/investigacion-e-innovacion/editorial/ | |
dc.title | Estudio de la fisuración por contracción plástica en losas de concreto con agregados reciclados y uso de microfibras | |
dc.type | Artículo de revista | |