dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorAbreu, Celina Wanderley
dc.creatorNishioka, Renato Sussumu
dc.creatorBalducci, Ivan
dc.creatorConsani, Rafael Leonardo Xediek
dc.date2014-05-20T14:05:28Z
dc.date2016-10-25T17:10:47Z
dc.date2014-05-20T14:05:28Z
dc.date2016-10-25T17:10:47Z
dc.date2012-10-01
dc.date.accessioned2017-04-05T21:34:50Z
dc.date.available2017-04-05T21:34:50Z
dc.identifierJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Hoboken: Wiley-blackwell, v. 21, n. 7, p. 535-539, 2012.
dc.identifier1059-941X
dc.identifierhttp://hdl.handle.net/11449/22972
dc.identifierhttp://acervodigital.unesp.br/handle/11449/22972
dc.identifier10.1111/j.1532-849X.2012.00871.x
dc.identifierWOS:000310803300005
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2012.00871.x
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/868279
dc.descriptionPurpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
dc.languageeng
dc.publisherWiley-Blackwell
dc.relationJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectStrain gauge
dc.subjectMorse taper implant
dc.subjectaxial load
dc.titleStraight and Offset Implant Placement under Axial and Nonaxial Loads in Implant-Supported Prostheses: Strain Gauge Analysis
dc.typeOtro


Este ítem pertenece a la siguiente institución