dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorPuga, Guilherme Morais
dc.creatorNakamura, Fábio Yuzo
dc.creatorSimões, Herbert Gustavo
dc.creatorKokubun, Eduardo
dc.creatorCampbell, Carmen Silvia Grubert
dc.date2013-09-30T19:28:30Z
dc.date2014-05-20T13:58:19Z
dc.date2013-09-30T19:28:30Z
dc.date2014-05-20T13:58:19Z
dc.date2009-06-01
dc.date.accessioned2017-04-05T21:18:51Z
dc.date.available2017-04-05T21:18:51Z
dc.identifierRevista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 15, n. 3, p. 209-213, 2009.
dc.identifier1517-8692
dc.identifierhttp://hdl.handle.net/11449/20718
dc.identifier10.1590/S1517-86922009000300009
dc.identifierS1517-86922009000300009
dc.identifierWOS:000267513000009
dc.identifierS1517-86922009000300009.pdf
dc.identifier0000-0002-9404-3444
dc.identifierhttp://dx.doi.org/10.1590/S1517-86922009000300009
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/866395
dc.descriptionO objetivo do presente estudo foi avaliar a aptidão aeróbia em testes de caminhada com carga externa aplicada por meio da inclinação da esteira, a partir da relação não linear entre inclinação da esteira e tempo até a exaustão em velocidade fixa. Doze indivíduos do gênero masculino com 23,2 ± 2,7 anos de idade, 74,0 ± 7,9kg de massa corporal e 23,7 ± 2,5kg·(m²)-1 de IMC, realizaram duas etapas de testes de caminhada em esteira ergométrica com velocidade fixa de 5,5km·h-1 em todos os testes e sobrecarga de intensidade aplicada por meio de inclinação da esteira (%). A etapa 1 consistiu de três testes retangulares até a exaustão voluntária, nas intensidades de 18%, 20% e 22% de inclinação, para determinação dos parâmetros do modelo de potência crítica por dois modelos lineares e um hiperbólico. A etapa 2 consistiu na determinação da intensidade correspondente ao máximo estado estável de lactato sanguíneo (MEEL). ANOVA demonstrou que o modelo hiperbólico (15,4 ± 1,1%) resultou em estimativa significativamente menor que os outros dois modelos lineares inclinação-tempo-1 (16,0 ± 1,0%) e hiperbólico linearizado tempo-1-inclinação (15,9 ± 1,0%), porém, houve alta correlação entre os modelos. Os dois modelos lineares superestimaram a intensidade do MEEL (14,1 ± 1,4%), e o modelo hiperbólico, mesmo sem diferença estatística, apresentou fraca correlação, com baixa concordância em relação ao MEEL. Conclui-se que a relação inclinação-tempo até a exaustão, em testes de caminhada, não permitem a estimativa de intensidade de exercício suportável por longo período de tempo.
dc.descriptionThe aim of the present study was to evaluate aerobic fitness during walk tests with workload increased by treadmill inclination, based on non-linear relationship between treadmill inclination and time until exhaustion in steady velocity. Twelve male subjects, 23.2 ± 2.7 years old, 74.0 ± 7.9 kg of body mass and 23.7 ± 2.5 kg·(m²)-1 of BMI, performed two phases of treadmill walk tests with steady velocity during all tests of 5.5 km·h-1 and intensity workload applied on the treadmill inclination (%). Phase 1 consisted of tree workout tests until voluntary exhaustion at 18%, 20% and 22% of inclination intensity, for critical power parameters determination, by using two linear models and a hyperbolic model. Phase 2 consisted of determination of the maximal blood lactate steady state (MLSS) intensity. ANOVA showed that the hyperbolic model (15.4 ± 1.1 %) underestimated both linear models: linear inclination-time-1 (16.0 ± 1.0 %) and hyperbolic linear time-1-inclination (15.9 ± 1.0 %); however, there was high correlation. Both linear models overestimated the MLSS intensity (14.1 ± 1.4%), and although there was no difference between the MLSS and the hyperbolic model, they had low correlation and there was a lower agreement. In conclusion, the inclination-time to exhaustion ratio in walk tests does not show an exercise intensity that can be bearable for a long period of time.
dc.languagepor
dc.publisherSociedade Brasileira de Medicina do Exercício e do Esporte
dc.relationRevista Brasileira de Medicina do Esporte
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjecttestes de caminhada
dc.subjectmáximo estado estável de lactato
dc.subjectinclinação crítica
dc.subjectwalk tests
dc.subjectmaximum lactate steady state
dc.subjectcritical inclination
dc.titleUtilização da relação potência-tempo até exaustão em testes de caminhada para avaliação da aptidão aeróbia
dc.typeOtro


Este ítem pertenece a la siguiente institución