dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorBianchi, Eduardo Carlos
dc.creatorAguiar, Paulo Roberto de
dc.creatorSantos, Marcelo de Almeida Souza
dc.creatorGonçalves, João Roberto
dc.creatorBarbosa, Darceny Zanetta
dc.creatorCatai, Rodrigo Eduardo
dc.date2013-09-30T18:31:35Z
dc.date2014-05-20T13:45:01Z
dc.date2013-09-30T18:31:35Z
dc.date2014-05-20T13:45:01Z
dc.date2003-06-01
dc.date.accessioned2017-04-05T20:50:56Z
dc.date.available2017-04-05T20:50:56Z
dc.identifierRem: Revista Escola de Minas. Escola de Minas, v. 56, n. 2, p. 107-112, 2003.
dc.identifier0370-4467
dc.identifierhttp://hdl.handle.net/11449/15799
dc.identifier10.1590/S0370-44672003000200008
dc.identifierS0370-44672003000200008
dc.identifierS0370-44672003000200008.pdf
dc.identifier0000-0003-0588-2228
dc.identifierhttp://dx.doi.org/10.1590/S0370-44672003000200008
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/862726
dc.descriptionEsse artigo tem como objetivo apresentar o projeto, a construção e os resultados obtidos no estudo da osseointegração com um torquímetro de alta precisão. Esse torquímetro, especialmente desenvolvido para este tipo de pesquisa, pode ser usado para desenvolver pesquisas odontológicas da osseointegração de implantes dentários. Os implantes foram feitos em sete coelhos que foram avaliados após 21 e 42 dias. Alguns coelhos sofreram estimulações ultra-sônicas em seus implantes, enquanto outros foram analisados sem se submeterem a estas estimulações. Os resultados mostraram o bom funcionamento do torquímetro e que o torque para remover o implante do coelho é diretamente proporcional ao tempo de osseintegração e que as estimulações ultra-sônicas podem influenciar o torque necessário para remover o implante em alguns casos.
dc.descriptionThis paper has as objective, to present the project, the construction and the results obtained in the study of the osseointegration with a torque gauge of high precision. The torque gage, especially developed for this research type, was used to improvement of odontological research on osseointegration of dental implant. The implants were done in seven rabbits that were available after 21 and 42 days. In some rabbits were made ultra-sonic stimulations at rabbits' implants. The results showed that the torque to remove the implant of the rabbits is directly proportional at the time of osseointegration and that the ultra-sonic stimulations can also influence the torque in some cases.
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.languagepor
dc.publisherEscola de Minas
dc.relationRem: Revista Escola de Minas
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTorquímetro
dc.subjectodontologia
dc.subjectosseointegração
dc.subjectimplantes dentários
dc.subjectTorque gauge
dc.subjectodontological research
dc.subjectosseointegration
dc.subjectdental implant
dc.titleDesenvolvimento de um torquímetro de precisão para o estudo do desempenho de implantes osseointegrados
dc.typeOtro


Este ítem pertenece a la siguiente institución