dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorRicardo Barao, Valentim Adelino
dc.creatorAssunção, Wirley Goncalves
dc.creatorTabata, Lucas Fernando
dc.creatorDelben, Juliana Aparecida
dc.creatorGomes, Erica Alves
dc.creatorSousa, Edson Antonio Capello
dc.creatorRocha, Eduardo Passos
dc.date2013-09-30T18:29:51Z
dc.date2014-05-20T13:43:35Z
dc.date2016-10-25T16:58:07Z
dc.date2013-09-30T18:29:51Z
dc.date2014-05-20T13:43:35Z
dc.date2016-10-25T16:58:07Z
dc.date2009-07-01
dc.date.accessioned2017-04-05T20:47:22Z
dc.date.available2017-04-05T20:47:22Z
dc.identifierJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 20, n. 4, p. 1066-1071, 2009.
dc.identifier1049-2275
dc.identifierhttp://hdl.handle.net/11449/15216
dc.identifierhttp://acervodigital.unesp.br/handle/11449/15216
dc.identifier10.1097/SCS.0b013e3181abb395
dc.identifierWOS:000268400400025
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181abb395
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/862256
dc.descriptionThis finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.
dc.languageeng
dc.publisherLippincott Williams & Wilkins
dc.relationJournal of Craniofacial Surgery
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDental implants
dc.subjectcomplete denture
dc.subjectoverdenture
dc.subjectattachment
dc.subjectfinite element analysis
dc.titleFinite Element Analysis to Compare Complete Denture and Implant-Retained Overdentures With Different Attachment Systems