dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorSisti, Karin Ellen
dc.creatorGarcia JR., Idelmo Rangel
dc.creatorGuastaldi, Antonio Carlos
dc.creatorAntoniolli, Andréia C. M. B.
dc.creatorRossi, Rafael De
dc.creatorBrochado Neto, Álvaro de L.
dc.date2013-09-30T19:53:35Z
dc.date2014-05-20T13:43:08Z
dc.date2013-09-30T19:53:35Z
dc.date2014-05-20T13:43:08Z
dc.date2006-01-01
dc.date.accessioned2017-04-05T20:46:05Z
dc.date.available2017-04-05T20:46:05Z
dc.identifierActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, p. 57-62, 2006.
dc.identifier0102-8650
dc.identifierhttp://hdl.handle.net/11449/15018
dc.identifier10.1590/S0102-86502006001000013
dc.identifierS0102-86502006001000013
dc.identifierS0102-86502006001000013.pdf
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502006001000013
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/862088
dc.descriptionOBJETIVO: Estudar a superfície de implantes osseointegráveis utilizando discos de titânio irradiados com feixe de laser. MÉTODOS: A amostra foi irradiada com feixes de laser de alta intensidade (Nd-YAG), posteriormente depositado hidróxiapatita e submetido a tratamento térmico. Foi analisada sob MEV (Microscópio Eletrônico de Varredura) e realizada análise morfológica qualitativa com microfotografias em vários aumentos. RESULTADOS: A superfície irradiada com laser apresentou deformidade superficial e característica isomórfica; a aplicação de hidroxiapatita pelo método de biomimético aumentou quantitativamente a área da superfície de titânio. CONCLUSÃO: A deposição de hidroxiapatita apresentou melhor característica isomórfica e aumento quantitativo da área superficial estudada, a amostra demonstrou características não encontradas nos implantes disposto no mercado.
dc.descriptionPURPOSE: The aim of this study was to analyse the surface of titanium implants using disc irradiated with lasers. METHODS: Titanium discs were irradiated with laser high insensitive (Nd-YAG), deposited durapatite and used thermal treatment. Sample received qualitative morphological analyse trough micrographics with many size in SEM (Scanning Electron Microscopy). RESULTS: Surface laser irradiation shows roughness and isomorphic characteristic. The durapatite amplified the titanium surface area by method biomimetic. CONCLUSION: The surface treatment presented more deposition of durapatite, roughness on the surface, better isomorphic characteristic and increase quantitative in titanium surface area, samples shows rugous, roughness and homogeneity there is not found in the implants available at the market.
dc.languageeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relationActa Cirúrgica Brasileira
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectLasers
dc.subjectTitânio
dc.subjectDurapatita
dc.subjectLasers
dc.subjectTitanium
dc.subjectDurapatite
dc.titleAnalyse titanium surface irradiated with laser, with and without deposited of durapatite
dc.typeOtro


Este ítem pertenece a la siguiente institución