dc.contributorIst Sci San Raffaele
dc.contributorDante Pazzanese Inst Cardiol
dc.contributorUniversidade Federal de São Paulo (UNIFESP)
dc.creatorBarille, Luigi
dc.creatorLandoni, Giovanni
dc.creatorPieri, Marina
dc.creatorRuggeri, Laura
dc.creatorMaj, Giulia
dc.creatorNigro Neto, Caetano [UNIFESP]
dc.creatorPasin, Laura [UNIFESP]
dc.creatorCabrini, Luca [UNIFESP]
dc.creatorZangrillo, Alberto
dc.date.accessioned2016-01-24T14:34:49Z
dc.date.accessioned2023-09-04T18:27:38Z
dc.date.available2016-01-24T14:34:49Z
dc.date.available2023-09-04T18:27:38Z
dc.date.created2016-01-24T14:34:49Z
dc.date.issued2013-12-01
dc.identifierJournal of Cardiothoracic and Vascular Anesthesia. Philadelphia: W B Saunders Co-Elsevier Inc, v. 27, n. 6, p. 1108-1113, 2013.
dc.identifier1053-0770
dc.identifierhttp://repositorio.unifesp.br/handle/11600/37051
dc.identifier10.1053/j.jvca.2013.02.016
dc.identifierWOS:000328181700006
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8614924
dc.description.abstractObjective: the authors measured cardiac index in unstable patients after cardiac surgery with the Pressure Recording Analytic Method (PRAM) and compared it with the reference method of thermodilution (ThD) with the pulmonary artery catheter; using the hypothesis that there were no significant differences between the 2 methods.Design: A prospective study.Setting: Cardiac surgery intensive care unit in a teaching hospital.Participants: Ninety-four measurements from 59 patients with ongoing high doses of inotropic drugs and/or an intra-aortic balloon pump for low-cardiac-output syndrome after cardiac surgery were studied.Interventions: the pulmonary artery catheter and the radial or femoral arterial catheter for measuring blood pressure were already in place for standard hemodynamic monitoring.Measurements and Main Results: the mean of the total Cl measurements was 2.94 +/- 0.67 L/min/m(2) with PRAM and 2.95 +/- 0.63 L/min/m(2) with ThD, with no significant difference according to the linear mixed models analysis. the PRAM and ThD techniques were similar in unstable patients without atrial fibrillation (mean bias 0.047 +/- 0.395 L/min/m(2) and a percentage error of 29%), while no agreement between PRAM and ThD was found in unstable patients with atrial fibrillation (mean bias 0.195 +/- 0.885 L/min/m(2) and a percentage error of 69%).Conclusion: Cardiac index measurements after cardiac surgery performed with PRAM and with ThD showed a good agreement in hemodynamically unstable patients given high doses of inotropes and/or an IABP in patients in sinus rhythm, but not in those with atrial fibrillation. (C) 2013 Elsevier Inc. All rights reserved.
dc.languageeng
dc.publisherElsevier B.V.
dc.relationJournal of Cardiothoracic and Vascular Anesthesia
dc.rightshttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.rightsAcesso restrito
dc.subjectpressure recording analytic method
dc.subjectPRAM
dc.subjectpulmonary artery catheter
dc.subjectcardiac index
dc.subjectcardiac surgery
dc.subjecthigh-risk patients
dc.subjectunstable patients
dc.subjectatrial fibrillation
dc.subjectanesthesia
dc.subjectintensive care
dc.subjectthermodilution
dc.titleCardiac Index Assessment by the Pressure Recording Analytic Method in Critically Ill Unstable Patients After Cardiac Surgery
dc.typeArtigo


Este ítem pertenece a la siguiente institución