dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorBarbarini Ferraz, Lucieni Cristina
dc.creatorSchellini, Silvana Artioli
dc.creatorHoyama, Erika
dc.creatorWludarski, Sheila Lordelo
dc.creatorPadovani, Carlos Roberto
dc.date2014-05-20T13:36:41Z
dc.date2016-10-25T16:53:38Z
dc.date2014-05-20T13:36:41Z
dc.date2016-10-25T16:53:38Z
dc.date2009-12-18
dc.date.accessioned2017-04-05T20:31:33Z
dc.date.available2017-04-05T20:31:33Z
dc.identifierInternational Journal of Ophthalmology. Xi An: Ijo Press, v. 2, n. 4, p. 291-293, 2009.
dc.identifier1672-5123
dc.identifierhttp://hdl.handle.net/11449/12630
dc.identifierhttp://acervodigital.unesp.br/handle/11449/12630
dc.identifierWOS:000282934000003
dc.identifierhttp://www.ijo.cn/en_publish/2009/4/200904003.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/860207
dc.descriptionAIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,
dc.languageeng
dc.publisherIjo Press
dc.relationInternational Journal of Ophthalmology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectpolyethylene implant
dc.subjectB ultrasound
dc.subjectrabbit
dc.subjectanophthalmic cavity
dc.titleGel and porous polyethylene implants for anophthalmic cavity reconstruction-evaluation using the B scan ultrasound
dc.typeOtro


Este ítem pertenece a la siguiente institución