dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorSoranz Filho, João Edward
dc.creatorMendes, Gustavo
dc.creatorTakahira, Regina Kiomi
dc.creatorSchellini, Silvana Artioli
dc.creatorPellizzon, Cláudia Helena
dc.date2014-05-20T13:36:26Z
dc.date2014-05-20T13:36:26Z
dc.date2012-08-01
dc.date.accessioned2017-04-05T20:31:01Z
dc.date.available2017-04-05T20:31:01Z
dc.identifierRevista Brasileira de Oftalmologia. Sociedade Brasileira de Oftalmologia, v. 71, n. 4, p. 227-232, 2012.
dc.identifier0034-7280
dc.identifierhttp://hdl.handle.net/11449/12547
dc.identifier10.1590/S0034-72802012000400004
dc.identifierS0034-72802012000400004
dc.identifierWOS:000310854600004
dc.identifierS0034-72802012000400004.pdf
dc.identifier0000-0003-3323-4199
dc.identifierhttp://dx.doi.org/10.1590/S0034-72802012000400004
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/860142
dc.descriptionOBJETIVO: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Para tanto a procura de um material de baixo custo e com biocompatibilidade tem sido uma constante na literatura. Portanto, esse trabalho teve como objetivo testar experimentalmente implante de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicose de toxicidade sistêmica do material. MÉTODOS: Para esse estudo foram utilizados coelhos Oryctolaguscuniculus submetidos à evisceração do globo ocular direito e posteriormente implantados com esfera de polietileno granulado de ultra-alto peso molecular e analisados por 15, 30, 90 e 180 dias pós-implante, com parâmetros macro, microscópios e bioquímicos. Os animais controles foram submetidos ao mesmo procedimento sem, entretanto a colocação do implante. RESULTADOS: Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros de peso e bioquímicos quando comparados ao grupo controle. O material implantado apresentou uma grande interação com o tecido do hospedeiro. CONCLUSÃO: Os resultados indicam que implante de polietileno granulado de alto peso molecular desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos.
dc.descriptionOBJECTIVE: Ocular changes in special due to volume loss in eviscerated cavities promote several psychological aesthetic and functional alterations to patients. For this reason, searches aiming at finding a material of low cost and biocompatibility have been constantly carried out. Test experimentally the implants constituted of ultra-high molecular weight granular polyethylene oflow cost, in orbits of rabbits subjected to surgical evisceration in several experimental times, evaluating the macro and microscope aspects besides the systemic toxicity of the material. METHODS: In this study we eviscerated the right ocular globe of rabbits of the species Oryctolaguscuniculus, implanted posteriorly a sphere of granular polyethylene of ultrahigh molecular weight and analysed the effects through macro, micro and biochemical parameters during 15, 30, 90 and 180 days after implantation.The control group were submitted the same procedure without the implants. RESULTS: This paper shows that the material used in the cavity does not present significant alteration in the weight and in the biochemistry of the animal; a good assimilation (integration) of the material implanted by the tissue formed was observed inside the implant. CONCLUSION: The results indicate that ultra-high molecular weight granular polyethylene implant developed by a national industry presents excellent integration in the model used supporting further use in tests with humans.
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.languagepor
dc.publisherSociedade Brasileira de Oftalmologia
dc.relationRevista Brasileira de Oftalmologia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAnoftalmia
dc.subjectOlho artificial
dc.subjectImplantes orbitários
dc.subjectPolietilenos
dc.subjectCoelhos
dc.subjectAnophthalmos
dc.subjectEye, artificial
dc.subjectOrbital implants
dc.subjectPolyethylenes
dc.subjectRabbits
dc.titleO uso de implantes orbitários de polietileno granulado de ultra-alto peso molecular no reparo de cavidades anoftálmicas
dc.typeOtro


Este ítem pertenece a la siguiente institución