dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorRahal, Sheila Canevese
dc.creatorSchellini, Silvana Artioli
dc.creatorMARQUES, Mariângela Esther Alencar
dc.creatorRanzani, José Joaquim Titton
dc.date2014-05-20T13:32:17Z
dc.date2016-10-25T16:50:42Z
dc.date2014-05-20T13:32:17Z
dc.date2016-10-25T16:50:42Z
dc.date2000-01-01
dc.date.accessioned2017-04-05T20:20:56Z
dc.date.available2017-04-05T20:20:56Z
dc.identifierBrazilian Journal of Veterinary Research and Animal Science. Faculdade de Medicina Veterinária e Zootecnia / Universidade de São Paulo, v. 37, n. 4, p. 00-00, 2000.
dc.identifier1413-9596
dc.identifierhttp://hdl.handle.net/11449/11016
dc.identifierhttp://acervodigital.unesp.br/handle/11449/11016
dc.identifier10.1590/S1413-95962000000400004
dc.identifierS1413-95962000000400004
dc.identifier0000-0002-9211-4093
dc.identifierhttp://dx.doi.org/10.1590/S1413-95962000000400004
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/858837
dc.descriptionForam eviscerados os globos oculares esquerdos de 32 ratos, linhagem Wistar, divididos em quatro grupos (A, B, C, D) constituídos, cada um, de cinco testemunhas e três controles. Nos animais-testemunha introduziu-se, dentro da capa córneo-escleral, uma esfera de resina acrílica (metilmetacrilato), previamente confeccionada e esterilizada por autoclavagem, ao passo que nos controles a cavidade eviscerada foi mantida sem prótese. Os ratos dos grupos A, B, C e D foram sacrificados respectivamente aos 7, 15, 30 e 90 dias de pós-operatório, quando os conteúdos orbitários esquerdos foram exenterados e preparados para o exame histopatológico. Observou-se que os animais-testemunha tiveram resposta inflamatória do tipo tecido de granulação ao redor da prótese de cavidade, com edema inflamatório da córnea especialmente nos grupos A e B, quando se iniciou a regressão da inflamação aguda. A cavidade orbitária manteve o tamanho em todos os grupos nos animais-testemunha e houve contração significativa nos animais-controle. Com estas observações, foi possível concluir que a esfera de resina acrílica é uma opção, de baixo custo e fácil confecção, para correção de defeito estético causado pela perda do globo ocular.
dc.descriptionThe ocular globe was eviscerated in 32 Wistar rats, divided in four groups (A, B, C, D) of eight animals each. Acrylic resin prosthesis was implanted into the corneoscleral membrane in five animals of each group. The other three did not receive the prosthesis. The methylmetacrylate sphere was manufactured and autoclaved. The animals from A, B, C and D groups were euthanized at 7, 15, 30 and 90 days after surgery, in the same order, and the orbital content was submitted to histopathological examination. A granulomatous inflammatory response surrounded the prosthesis and inflammatory edema in the cornea was observed mainly in the animals of A and B groups. The volume of the anophthalmic cavity was replaced in all animals that received the prosthesis, but not in the animals that did not received it. It was concluded that intraocular prosthesis of acrylic resin is a cosmetic alternative for correction of the defect produced by the lost of the ocular globe.
dc.languagepor
dc.publisherUniversidade de São Paulo (USP), Faculdade de Medicina Veterinária e Zootecnia (FMVZ)
dc.relationBrazilian Journal of Veterinary Research and Animal Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPrótese
dc.subjectMetilmetacrilatos
dc.subjectRatos
dc.subjectOlho artificial
dc.subjectProsthesis
dc.subjectMethylmethacrylate
dc.subjectRats
dc.subjectEye artificial
dc.titleEmprego de prótese intra-ocular de resina acrílica. Estudo experimental em ratos
dc.typeOtro


Este ítem pertenece a la siguiente institución