dc.contributor | Universidade Estadual Paulista (UNESP) | |
dc.creator | Azevedo, Anibal T. de | |
dc.creator | Castro, Carlos A. | |
dc.creator | Oliveira, Aurelio R. L. | |
dc.creator | Soares, Secundino | |
dc.date | 2014-05-20T13:27:57Z | |
dc.date | 2014-05-20T13:27:57Z | |
dc.date | 2009-06-01 | |
dc.date.accessioned | 2017-04-05T20:10:05Z | |
dc.date.available | 2017-04-05T20:10:05Z | |
dc.identifier | Sba: Controle & Automação Sociedade Brasileira de Automatica. Sociedade Brasileira de Automática, v. 20, n. 2, p. 206-216, 2009. | |
dc.identifier | 0103-1759 | |
dc.identifier | http://hdl.handle.net/11449/9273 | |
dc.identifier | 10.1590/S0103-17592009000200008 | |
dc.identifier | S0103-17592009000200008 | |
dc.identifier | S0103-17592009000200008.pdf | |
dc.identifier | http://dx.doi.org/10.1590/S0103-17592009000200008 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/857453 | |
dc.description | Este trabalho apresenta uma nova formulação do problema de fluxo de potência ótimo corrente contínua com restrições de segurança de três tipos: perda de ramo, perda de gerador e múltiplas perdas. A formulação emprega um modelo de fluxo em redes com restrições adicionais de igualdade e desigualdade e função objetivo quadrática separável que é eficientemente resolvido por um método de pontos interiores preditor-corretor. Técnicas de esparsidade são utilizadas para explorar a estrutura matricial do problema. Estudos de caso para o Sistema Interligado Nacional com 3535 barras e 4238 ramos são apresentados e discutidos, a fim de demonstrar que o modelo proposto pode ser resolvido através de um método de pontos interiores de maneira eficiente, fornecendo soluções que respeitam as restrições de segurança em um tempo computacional razoável. | |
dc.description | This paper presents a new formulation for the security constrained optimal active power flow problem which enables the representation of three basic constraints: branch outage, generator outage and multiple equipment congestion. It consists of a network model with additional linear equality and inequality constraints and quadratic separable objective function, which is efficiently solved by a predictor-corrector interior point method. Sparsity techniques are used to exploit the matricial structure of the problem.Case studies with a 3,535-bus and a 4,238-branch Brazilian power system are presented and discussed, to demonstrate that the proposed model can be efficiently solved by an interior point method, providing security constrained solutions in a reasonable time. | |
dc.description | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.language | eng | |
dc.publisher | Sociedade Brasileira de Automática | |
dc.relation | Sba: Controle & Automação Sociedade Brasileira de Automatica | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Segurança | |
dc.subject | despacho de potência ativa | |
dc.subject | fluxo de potência ótimo | |
dc.subject | fluxo em redes | |
dc.subject | controle de fluxo de potência | |
dc.subject | método de pontos interiores | |
dc.subject | Security | |
dc.subject | active power dispatch | |
dc.subject | optimal power flow | |
dc.subject | network model | |
dc.subject | power flow controls | |
dc.subject | interior point method | |
dc.title | Security constrained optimal active power flow via network model and interior point method | |
dc.type | Otro | |