dc.creatorPeixoto, Aldo
dc.creatorSantos, Sergio F.F.
dc.creatorMendes, Roger
dc.creatorCrowley, Susan
dc.creatorMaldonado, Rafael
dc.creatorOrias, Marcelo
dc.creatorMansoor, George A.
dc.creatorWhite, William B.
dc.date2000-12-31
dc.date.accessioned2023-08-30T17:09:05Z
dc.date.available2023-08-30T17:09:05Z
dc.identifierhttp://pa.bibdigital.ucc.edu.ar/3921/1/A_Peixoto_Santos_Mendes_Crowley_Maldonado_Orias_Mansoor_White.pdf
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8539650
dc.descriptionAmbulatory blood pressure monitoring (ABPM) has been increasingly used in hemodialysis (HD) practice and research; however, no study has evaluated the reproducibility of ABPM in this population. To address this question, we performed 48-hour interdialytic ABPM on 21 HD patients (mean age, 53 ± 16 years; 7 women) on two different occasions 68 ± 34 days (range, 30 to 154 days) apart. To qualify for the protocol, patients had to be at the same dry weight and on the same vasoactive drug regimen at both monitoring periods. BP was analyzed according to three different methods: isolated pre-HD and post-HD values, average pre-HD and post-HD values for the five HD sessions surrounding each monitoring period, and 48-hour interdialytic ABPM. Reproducibility was determined by analysis of the SD of the differences (SDD) between the two monitoring periods and the coefficient of variation of each method of BP determination. Our results show better reproducibility of ABPM (SDD, 10.6/6.6 mm Hg; coefficient of variation, 7.5%/8.1%) compared with isolated pre-HD BP (SDD, 24.4/11.3 mm Hg; coefficient of variation, 16.7%/14.1%) or post-HD BP (SDD, 16.8/14.5 mm Hg; coefficient of variation, 11.7%/17.8%), and averaged pre-HD BP (SDD, 14.7/7.2 mm Hg; coefficient of variation, 10.1%/9.1%) or post-HD BP (SDD, 12.4/8.7 mm Hg; coefficient of variation, 8.9%/11.1%). The reproducibility of the decrease in BP during sleep was poor, with up to 43% of the subjects changing dipping category within or between interdialytic periods. We conclude that ABPM is the most accurate method to study BP in HD patients over time. However, variability is significant, and there is poor reproducibility of the nocturnal decline in BP
dc.descriptionFil: Peixoto, Aldo. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Santos, Sergio F.F. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Mendes, Roger. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Crowley, Susan. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Maldonado, Rafael. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Orias, Marcelo. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: Mansoor, George A. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.descriptionFil: White, William B. Universidad Católica de Córdoba. Facultad de Ciencias de la Salud; Argentina
dc.formatapplication/pdf
dc.languagespa
dc.relationhttp://pa.bibdigital.ucc.edu.ar/3921/
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/10.1053/ajkd.2000.19100
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es
dc.sourcePeixoto, Aldo ORCID: https://orcid.org/0000-0003-1525-2991 <https://orcid.org/0000-0003-1525-2991>, Santos, Sergio F.F., Mendes, Roger ORCID: https://orcid.org/0000-0001-5256-8771 <https://orcid.org/0000-0001-5256-8771>, Crowley, Susan ORCID: https://orcid.org/0000-0001-8143-5759 <https://orcid.org/0000-0001-8143-5759>, Maldonado, Rafael, Orias, Marcelo ORCID: https://orcid.org/0000-0002-9750-3389 <https://orcid.org/0000-0002-9750-3389>, Mansoor, George A. and White, William B. (2000) Reproducibility of ambulatory blood pressure monitoring in hemodialysis patients. American Journal of Kidney Diseases, 36 (5). pp. 983-990. ISSN 0272-6386
dc.subjectR Medicina (General)
dc.titleReproducibility of ambulatory blood pressure monitoring in hemodialysis patients
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/acceptedVersion


Este ítem pertenece a la siguiente institución