Determinación de la concentración de esmolol en plasma por cromatografía gaseosa acoplada a un detector de nitrógeno-fósforo
Determination of esmolol concentration in plasm by gas chromatography coupled to a nitrogen-phosphorus detector
dc.creator | González Ospina, Julián Arbey | |
dc.creator | Parra, Sergio | |
dc.creator | Fuentes González, Jesualdo | |
dc.creator | Cuesta González, Fanny | |
dc.date | 2021-09-06T13:21:40Z | |
dc.date | 2021-09-06T13:21:40Z | |
dc.date | 2004 | |
dc.date.accessioned | 2023-08-28T20:59:11Z | |
dc.date.available | 2023-08-28T20:59:11Z | |
dc.identifier | 0121-4004 | |
dc.identifier | http://hdl.handle.net/10495/22225 | |
dc.identifier | 2145-2660 | |
dc.identifier | https://revistas.udea.edu.co/index.php/vitae/article/view/453 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/8486990 | |
dc.description | RESUMEN: Este artículo describe el desarrollo y validación de un método analítico alternativo para la cuantificación de esmolol, un β-bloqueador de acción ultra corta, en plasma humano, usando un cromatógrafo de gases acoplado a un detector de Nitrógeno–Fósforo. El procedimiento analítico es preciso y exacto. Con una precisión en el rango de: 4.1% al 19.7%, una exactitud en un rango de: 2.5% al 25.9%. La curva es lineal para concentraciones de concentraciones en el rango de 6,25-1000 ng/ml; con un coeficiente de correlación promedio de 0.9995 cuando se usa como estándar interno propranolol. Los tiempos de retención para el esmolol y el propanolol son de 12.87 ± 0.04 min y 11.65 ± 0.05 min respectivamente. El procedimiento es simple y sensible ya que no requiere de reextracción o derivatización del esmolol y su límite de cuantificación es de 6.25 ng/mL. Por esto, permite medir concentraciones plasmáticas de esmolol en individuos a los que se les administren dosis bajas. | |
dc.description | ABSTRACT: This paper describes the development and validation of an alternative analytic method using a gas chromatograph coupled to a Nitrogen – Phosphorous detector for the quantification of esmolol. This compound is an ultra-short acting β-blocker in human plasma. The analytical procedure is precise, and accurate (precision and accuracy ranges are 4.1 to 19.7 % and 2.5 to 25 % respectively). The calibration curve is lineal for concentrations in the range 6.25-1000 ng/mL. with a correlation coefficient of 0.9995, using propranolol as internal standard. The retention times of esmolol and propranolol are 12.87± 0.04 and 11.65 ± 0.05 min respectively. This procedure is simple and sensitive since it does not require re-extraction or derivatization of esmolol, and the quantification limit is 6.25ng/mL. The method allows to quantify plasmatic concentrations for individuals with low esmolol doses. | |
dc.description | COL0049453 | |
dc.description | COL0039902 | |
dc.format | 7 | |
dc.format | application/pdf | |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Universidad de Antioquia, Facultad de Ciencias Farmacéuticas y Alimentarias | |
dc.publisher | Grupo de Estudio e Investigaciones Biofarmacéuticas | |
dc.publisher | Grupo de Investigación en Farmacología y Toxicología | |
dc.publisher | Medellín, Colombia | |
dc.relation | Vitae | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://creativecommons.org/licenses/by-nc-sa/2.5/co/ | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
dc.subject | Antagonistas Adrenérgicos beta | |
dc.subject | Adrenergic beta-Antagonists | |
dc.subject | Estudio de Validación | |
dc.subject | Validation Study | |
dc.subject | Cromatografía de Gases | |
dc.subject | Chromatography, Gas | |
dc.subject | Esmolol | |
dc.subject | β-bloqueadores | |
dc.subject | Niveles plasmáticos | |
dc.title | Determinación de la concentración de esmolol en plasma por cromatografía gaseosa acoplada a un detector de nitrógeno-fósforo | |
dc.title | Determination of esmolol concentration in plasm by gas chromatography coupled to a nitrogen-phosphorus detector | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dc.type | http://purl.org/coar/resource_type/c_2df8fbb1 | |
dc.type | https://purl.org/redcol/resource_type/ART | |
dc.type | Artículo de investigación |