dc.contributorAndrade Maquilón, Mauricio
dc.contributorGallego Londoño,Jonathan
dc.creatorSánchez Durango, Yenifher
dc.date2022-08-17T14:14:25Z
dc.date2022-08-17T14:14:25Z
dc.date2022
dc.date.accessioned2023-08-28T20:15:32Z
dc.date.available2023-08-28T20:15:32Z
dc.identifierhttps://hdl.handle.net/10495/30078
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8476304
dc.descriptionRESUMEN : Un endoscopio es un dispositivo médico que permite al personal de salud aumentar el campo visual al interior del organismo del paciente, permitiendo la obtención de imágenes directas del cuerpo en lugares donde sería imposible introducir algún instrumento. En el Hospital San Vicente Fundación de Medellín tiene 25 endoscopios, 18 equipos para vía digestiva y 7 para vía aérea, llevando a cabo un aproximado de 7.880 procedimientos de endoscopia al año, lo que corresponde a una gran cantidad de procedimientos, por lo cual es importante tener presente la funcionalidad y el proceso de lavado de los endoscopios, ya que todos los pacientes deben ser considerados como una fuente potencial de infección, y todos los endoscopios deben ser descontaminados con el mismo grado de rigurosidad después de cada procedimiento endoscópico. La falta de cumplimiento con las recomendaciones puede no solo provocar la transmisión de patógenos, sino también dar lugar a errores en el diagnóstico, mal funcionamiento de los instrumentos, y acortamiento de su vida útil. Por este motivo se planteó la creación de un prototipo funcional que sirva de forma auxiliar para el reprocesamiento de endoscopios, de manera que se desarrollará en tres etapas. Previamente al desarrollo, fue necesario un estudio de campo sobre el proceso de reprocesamiento que se lleva a cabo en el hospital, de manera que se tuviera un contexto claro de las fases de lavado, detergentes, desinfectantes utilizados y el tiempo empleado para estas actividades. La primera etapa del desarrollo del prototipo consistió en seleccionar los componentes electrónicos, mecánicos y estructurales que harían parte del prototipo funcional, realizando consultas en tiendas electrónicas, páginas web y con terceros que proporcionan información sobre los posibles componentes que podrían ser implementados, de manera que se pudieran tener varias opciones y realizar una selección adecuada. Posteriormente, se procede a implementar la segunda etapa del desarrollo, la cual corresponde a ensamblar y fabricar el prototipo funcional basado en la elaboración del código y articulación de los componentes, donde la programación de la pantalla en Arduino era un paso muy importante, para esto se debió instalar varias librerías y buscar información sobre los comandos necesarios para su programación. El código está dividido en varias funciones que permiten visualizar la interfaz, el manejo del touch y el contador de tiempo regresivo, de manera que los auxiliares u operarios que realicen el proceso de lavado de los equipos puedan escoger entre dos opciones, 3 minutos para la fase de lavado con jabón enzimático y 5 minutos para la implementación del desinfectante, por último, se realiza el montaje y fabricación de la carcasa que alberga el prototipo. La última etapa del desarrollo consiste en verificar que el funcionamiento del prototipo funcional fabricado cumpla con el protocolo de reprocesamiento de endoscopios establecido por el hospital, tomando un control de calidad con las citillas de verificación, que proporcionan información del estado del desinfectante y la correcta implementación de los protocolos en el hospital, de manera que si hay un cambio de color en este insumo, puede ser porque no se sigue adecuadamente el protocolo de limpieza del hospital.
dc.descriptionABSTRACT : An endoscope is a medical device that allows health care personnel to increase the visual field inside the patient's body, allowing direct images of the body to be obtained in places where it would be impossible to introduce any instrument. The San Vicente Fundación Hospital in Medellín has 25 endoscopes, 18 for the digestive tract and 7 for the airway, carrying out approximately 7,880 endoscopy procedures per year, which corresponds to a large number of procedures, so it is important to keep in mind the functionality and washing process of the endoscopes, since all patients should be considered as a potential source of infection and all endoscopes should be decontaminated with the same degree of rigorousness after each endoscopic procedure. Failure to comply with the recommendations may not only result in the transmission of pathogens, but also lead to errors in diagnosis, instrument malfunction, and shortened instrument life.For this reason, the creation of a functional prototype to serve as an auxiliary form for the reprocessing of endoscopes was proposed so that it would be developed in three stages. The first to the development, it was necessary to conduct a field study on the reprocessing process carried out in the hospital, in order to have a clear context of the washing phases, detergents, disinfectants used, and the time used for these activities. The first stage of the prototype development consisted of selecting the electronic, mechanical, and structural components that would be part of the functional prototype, by consulting electronic stores, web pages, and third parties that provide information on the possible components that could be implemented, so that several options could be available and an adequate selection could be made. Subsequently, we proceeded to implement the second stage of development, which corresponds to assembling and manufacturing the functional prototype based on the development of the code and articulation of the components, where the programming of the screen in Arduino was a very important step, for this we had to install several libraries and seek information on the necessary commands for programming. The code is divided into several functions that allow visualizing the interface, the handling of the touch, and the countdown timer, so that the assistants or operators who perform the washing process of the equipment can choose between two options, 3 minutes for the washing phase with enzymatic soap and 5 minutes for the implementation of the disinfectant, finally, the assembly and manufacture of the case that houses the prototype is performed. The last stage of the development consists of verifying that the functioning of the manufactured functional prototype complies with the endoscope reprocessing protocol established by the hospital, taking quality control with the verification cells, which provide information on the state of the disinfectant and the correct implementation of the protocols in the hospital, so that if there is a color change in this input, it may be because the hospital's cleaning protocol is not properly followed.
dc.format61
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.publisherMedellín - Colombia
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectEndoscopios
dc.subjectEndoscopes
dc.subjectEquipos y Suministros
dc.subjectEquipment and Supplies
dc.subjectPrueba de Estudio Conceptual
dc.subjectProof of Concept Study
dc.subjectSurfactantes
dc.subjectsurfactants
dc.subjecthttp://aims.fao.org/aos/agrovoc/c_7529
dc.titlePrototipo auxiliar para el reprocesamiento de endoscopios en el Hospital San Vicente Fundación
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.typeinfo:eu-repo/semantics/draft
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.typehttps://purl.org/redcol/resource_type/TP
dc.typeTesis/Trabajo de grado - Monografía - Pregrado


Este ítem pertenece a la siguiente institución