dc.descriptionEn el último año hubo un incremento en la propagación de incendios forestales a nivel nacional. Esto se debe a la duración del fenómeno del niño y a las quemas por intervención humana. Una de las zonas más afectadas en los últimos años ha sido la vía parque Isla Salamanca. Los planes del gobierno para el control de incendios forestales no son eficaces permitiendo que se extiendan por la zona afectada. La implementación de un sistema de detección temprana disminuiría el tamaño del área afectada y aumentaría el tiempo de acción para sofocar el incendio. Se propuso realizar el prototipo de una red inalámbrica de sensores para el monitoreo de la vía parque Isla Salamanca implementando sensores de humo. El prototipo funciona en área abierta de 400 m2. El sistema debía detectar la presencia de máximo dos focos en la zona, y su localización se realiza por medio de una página web local usando un mapa. El caso real de implementación es un área de 1 km2.Para el diseño del sistema no se podría utilizar la red celular ni a la red eléctrica. El sistema únicamente mediría la presencia de humo. Los nodos son estáticos y no se incorpora un sistema de recarga para las baterías. El sistema consta de tres etapas; la de detección que utilizan microcontroladores PIC16F88 para leer la información generada por el sensor de gases MQ135; la etapa de comunicación se utiliza módulos Xbee para recepción y transmisión; y la etapa de visualización implementa una página web basada en lenguajes de programación JavaScript, PHP, CSS y Python. En esta se visualizan los nodos y las alertas generadas. Se logró detectar fuentes de humo alrededor de los sensores a una distancia máxima de 5 metros. Se utilizaron asadores para la simulación de los focos de incendio. La altura de instalación de los nodos es importante debido a la nube de humo que se genera. Se debe mejorar el hardware para disminuir la posible contaminación ambiental y para protegerlo contra intervención animal y humana.
dc.descriptionThe last year there was an increase in the spread of forest fires at the nationwide. This is due to the length of the child's phenomenon and the burning generated by humans. In recent years, one of the most affected areas has been Isla Salamanca Parkway. The government's plans for control fire forest generation are ineffective, allowing them to spread across the affected area. Implementation of an early detection system would decrease the size of the affected area and increase the time of action to quell the fire. It was proposed to carry out the prototype of a wireless sensor network for the monitoring of the Isla Salamanca parkway by implementing smoke sensors. The prototype works in an open area of 400 m2. The system had to detect the presence of two fire foci, and it is located using a local web page with a map of the area. The real implementation case is an area of 1 km2. The system design could not use the cellular network neither the supply voltage grid. The system would only measure the presence of smoke. The nodes are static and a recharging system for the batteries is not included. The system consists of three stages; The detection stage use PIC16F88 microcontrollers to read the information generated by the gas sensor MQ135; The communication stage uses Xbee modules for reception and transmission; And the visualization stage implements a web page based on JavaScript, PHP, CSS and Python. This web page displays the generated nodes and alerts. Smoke sources around the sensors were detected at a maximum range of 5 meters. Steakhouses were used for the simulation of fire sources. Installation height of the nodes is really relevant because of the smoke cloud generated by the fire foci. The hardware should be improved to reduce possible environmental contamination and to protect against animal and human intervention.
dc.formatimage/png
dc.formatapplication/pdf
dc.formatimage/png
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.formatimage/png
dc.languagespa
dc.publisherBarranquilla, Universidad del Norte, 2016
dc.rightsUniversidad del Norte
dc.rightsopenAccess
dc.subjectIncendios, Sensores de Humo, Módulos Xbee, Prototipo, Vía Parque Isla Salamanca, Nodos
dc.subjectFires, Smoke Sensors, Modules Xbee, Prototype, Isla Salamanca Parkway, Nodes
dc.titleSistema de Detección Temprana de Incendios Forestales