Structural system based on load-bearing walls for the Mario Santo Domingo science and language building

dc.contributorArteta Torrents, Carlos Alberto
dc.creatorSepúlveda Almarales, Víctor Hugo
dc.creatorPrasca Atencia, Ana María
dc.creatorBertel Ibarra, Sebastián Camilo
dc.creatorAndrade Paredis, Andrés Felipe
dc.date2022-07-06T21:15:25Z
dc.date2022-07-06T21:15:25Z
dc.date2022-06-03
dc.date.accessioned2023-08-25T15:50:58Z
dc.date.available2023-08-25T15:50:58Z
dc.identifierhttp://hdl.handle.net/10584/10682
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8429296
dc.descriptionEl edificio Mario Santo domingo se encuentra ubicado en el kilómetro 5 vía Puerto Colombia dentro de las instalaciones de la Universidad del Norte. Este edificio pretende suplir la necesidad aumentar la planta física de dicha universidad. El sistema constructivo de la propuesta se basa en muros de carga resistentes a momento con capacidad de resistir la carga axial demandada por el uso y constitución del edificio, además de un pórtico no resistente a momento pero que es capaz de transmitir cargas hacia la cimentación. El sistema se diseñó para una capacidad moderada de disipación de energía DMO, y suponiendo una zona de amenaza sísmica intermedia, usando los datos de coeficiente que representa la aceleración y velocidad horizontal pico efectiva correspondientes a la ciudad de Santa Marta. Para el análisis de la carga sísmica, se calculó el peso sísmico de todos los elementos de la estructura y las fuerzas horizontales que serían provocadas por un eventual sismo y se determinó que la estructura es capaz de disipar un 7,8% de su peso. En total la estructura requiere un total de 520000 kg de acero y 4545,14 m3 de concreto.
dc.descriptionThe Mario Santo Domingo building is located at kilometer 5 via Puerto Colombia within the facilities of the Universidad del Norte. This building aims to meet the need to increase the physical plant of said university. The construction system of the proposal is based on moment-resistant load-bearing walls with the capacity to resist the axial load demanded by the use and constitution of the building, in addition to a non-moment-resistant frame that is capable of transmitting loads to the foundation. The system was designed for a moderate DMO energy dissipation capacity, and assuming an intermediate seismic hazard zone, using the coefficient data that represents the acceleration and effective peak horizontal velocity corresponding to the city of Santa Marta. For the analysis of the seismic load, the seismic weight of all the elements of the structure and the horizontal forces that would be caused by an eventual earthquake were calculated, and it was determined that the structure is capable of dissipating 7.8% of its weight. In total, the structure requires a total of 520000 kg of steel and 4545,14 m3 of concrete.
dc.formatimage/jpeg
dc.formatimage/jpeg
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languageeng
dc.publisherBarranquilla, Universidad del Norte, 2022
dc.rightsUniversidad del Norte
dc.rightsopenAccess
dc.subjectDMO
dc.subjectMuros de carga
dc.subjectEdificaciones
dc.subjectLoad-bearing walls
dc.subjectBuildings
dc.titleSistema estructural basado en muros de carga para el edificio de ciencias e idiomas Mario Santo Domingo
dc.titleStructural system based on load-bearing walls for the Mario Santo Domingo science and language building
dc.typearticle