dc.descriptionObjetivo: Determinar a concordância da medida da resistência das vias aéreas (RVA) pela técnica interrupter resistance (Rint, resistência do interruptor) com a do método pletismográfico para fins de aplicabilidade clínica. Métodos: A técnica Rint foi realizada com os pacientes em posição sentada, em expiração, utilizando clipe nasal e com suporte das bochechas. O exame pletismográfico foi realizado de acordo com protocolos padronizados. As medidas foram realizadas antes e após a administração inalatória de um broncodilatador via spray dosimetrado com espaçador. Resultados: Avaliamos 99 pacientes consecutivos encaminhados para o Hospital de Clínicas de Porto Alegre, Porto Alegre (RS), para a realização de testes de função pulmonar, com idades entre 18 e 82 anos. Desses, 52 eram mulheres. Houve boa concordância entre os métodos (r = 0,8; coeficiente de correlação intraclasse = 0,8) nos pacientes com VEF1 ≥ 60% do previsto. Os valores de Rint foram menores que os da RVA por pletismografia em indivíduos mais graves. Entretanto, houve boa concordância entre Rint ≥ 4 cmH2O • L−1 • s−1 e RVA por pletismografia > 2,5 cmH2O • L−1 • s −1 (razão de verossimilhança > 8 e coeficiente kappa = 0,73). Conclusões: A concordância entre o Rint e a RVA por pletismografia foi boa nos indivíduos menos graves. A concordância para um diagnóstico de aumento da RVA entre os dois métodos também foi forte. A técnica Rint é um método potencialmente útil na prática assistencial em adultos.
dc.descriptionObjective: To determine the agreement between interrupter resistance (Rint) and airway resistance (Raw) by plethysmography in order to verify the clinical applicability of the interrupter technique. Methods: The Rint technique was performed with the patients in a sitting position, during exhalation, with a nose clip and cheek support. Plethysmography was carried out in accordance with standard protocols. All measurements were taken prior to and after the administration of an inhaled bronchodilator via a metered dose inhaler with a spacer. Results: The study comprised 99 consecutive patients referred to the Porto Alegre Hospital de Clínicas, located in the city of Porto Alegre, Brazil, for pulmonary function testing. Patient ages ranged from 18 to 82 years, and 52 of the patients were women. In the patients with FEV1 ≥ 60% of predicted, there was good agreement between the methods (r = 0.8; intraclass correlation coefficient = 0.8). The Rint values were lower than were those of Raw by plethysmography in the patients with more severe disease. However, there was good agreement between Rint ≥ 4 cmH2O • L−1 • s−1 and Raw by plethysmography > 2.5 cmH2O • L−1 • s−1 (likelihood ratio > 8; kappa coefficient = 0.73). Conclusions: In the patients with less severe disease, there was good agreement between Rint and Raw by plethysmography. The agreement between the two methods was also strong regarding the detection of an increase in Raw. The Rint technique is a potentially useful method for the evaluation of adult patients.
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagepor
dc.relationJornal brasileiro de pneumologia. Brasília, DF. Vol. 37, n. 1 (2011), p. 61-68
dc.rightsOpen Access
dc.subjectObstrução das vias respiratórias
dc.subjectPletismografia
dc.subjectTestes de função respiratória
dc.subjectPlethysmography
dc.subjectAirway resistance
dc.subjectDiagnostic techniques
dc.subjectRespiratory system
dc.subjectRespiratory function tests
dc.subjectAirway obstruction/diagnosis
dc.titleUma nova abordagem na determinação da resistência das vias aéreas : técnica do interruptor vs. pletismografia
dc.titleA new approach to the determination of airway resistance : interrupter technique vs. plethysmography
dc.typeArtigo de periódico
dc.typeNacional


Este ítem pertenece a la siguiente institución